background image

ACTIVE BLAST CHILLERS

10/15/28 kg

DCA01

2010-05-28

The Company reserves the right to alter technical specifications without prior notice.

www.zanussiprofessional.com

ZANUSSI

P R O F E S S I O N A L

TROLLEY FOR 10XGN1/1 ROLL IN RACK

922130

TROLLEY FOR 10X1/1 & 2/1 ROLL IN RACK

922128

ROLL-IN RACK SUPPORT BC+BCF 28KG 10GN1/1

881518

RILSAN COATED GRID

881061

881061

PRINTER FOR HACCP BASIC VERSION

881532

881532

881532

PLASTIC COATED GRID-600X400 MM

880864

880864

PAIR OF 1/1 GN AISI 304 S/S GRIDS

921101

921101

921101

KIT TO CONVERT TO 10X1/1 SLIDE-IN RACK

922201

KIT HACCP EKIS

922166

922166

922166

KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW

880183

880183

880183

COOK&CHILL KIT-6 GN OVEN/15KG BL.CHILLER

881528

80 MM PITCH SIDE HANGERS 10X1/1 GAS 0VEN

922116

80 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN

922115

60 MM PITCH SIDE HANGERS 10X1/1 GAS OVEN

922122

60 MM PITCH SIDE HANGERS 10X1/1 ELE.OVEN

922121

4 WHEELS FOR BLAST CHILLERS

881097

881097

4 FEET FOR UNDERCOUNTER BLAST CHILLER

881493

3-POINT-SENSOR PROBE-BL.C/FREEZERS LW

880212

880212

1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW

880213

880213

880213

BC10A

110780

BC15A

110717

BC28A

110718

ACCESSORIES

MODELS

OPTIONAL ACCESSORIES

 

The control unit provides several 

operating settings: time/core 
temperature according to NF and UK 
regulations, time/air 
temperature/probe personalised 
according to national regulations, 
sterilizing cycle: UV lamps built-in 
(on request), 3 single sensor or 
3-sensor temperature probes (as 
accessory), ideal for meats, 
automatic defrosting and manual 
defrosting. All parameters are 
programmable.

 

The control unit provides two large 

displays to read out: time, core 
temperature, residual time, alarms, 
service information. 

 

Two customizable cycles for each 

operating modes, allowing setting 
time and air temperature. These two 
programs (P1-P2) can be converted 
into ice-cream specialist cycles 
(shape maintenance and holding). 

 

All information related to the 

different operating models are 
recorded: date, time, cycle, core 
temperature, holding temperature, 
HACCP accordance. 

 

 An audible alarm starts when the 

cycle ends or terminates abnormally. 

 

Chilling times can vary according 

to food quantity, density, moisture 
contents and type of containers.

 

Internal and external finishing in 

304 AISI stainless steel and 
backpanel in galvanized steel. 

 

HCFC, CFC and HFC free 

insulation (Cyclopentane), HCFC 
and CFC free refrigerant gas 
(R404a).

 

Developed and produced in ISO 

9001 and ISO 14001 certified 
factory. 

 

Inner cell with rounded corners. 

 

Door equipped with removable 

magnetic gasket with hygienic 
design. 

 

Evaporator with antirust 

protection. 

 

Ventilator swinging panel foreasy 

access to the evaporator.  

 

Automatic heated door frame. 

 

Thermostatic expansion valve to 

optimize the cooling unit efficiency.  

 

Adjustable feet 150 mm high 

(except for code 110780). 

 

Stand alone printer as accessory.

 

PC connection as accessory, gate 

RS 485. 

 

No water connections required: 

Waste water can be plumbed into 
drain, but can also be collected in an 
optional waste container. 

 

  
  
 

*NF HYGIENE ALIMENTAIRE

certifying authority: AFAQ AFNOR 
CERTIFICATION. Adress:11, Avenue Francis de 
Pressense - 93571 Saint-Denis La Plaine Cedex 
- France. Conformity with regulation NF031. 
Certified guarantees: fitness for cleaning, thermal 
performance

Summary of Contents for 110717

Page 1: ...ERISTICS MODELS TECHNICAL DATA RANGE COMPOSITION Chilling means bringing the temperature of cooked food from 90ºC to 3 C in a short time lap to minimize bacteria proliferation and avoid loss of food consistency and texture The ZANUSSI easyChill Blast Chillers reduce temperature to 3 C at food core in less than 90 minutes After the Blast Chilling a holding cycle starts automatically to maintain foo...

Page 2: ...nd manual defrosting All parameters are programmable The control unit provides two large displays to read out time core temperature residual time alarms service information Two customizable cycles for each operating modes allowing setting time and air temperature These two programs P1 P2 can be converted into ice cream specialist cycles shape maintenance and holding All information related to the ...

Page 3: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC10A 110780 LEGEND 110780 ...

Page 4: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC15A 110717 LEGEND 110717 ...

Page 5: ...8 kg DCA01 2010 05 28 The Company reserves the right to alter technical specifications without prior notice www zanussiprofessional com ZANUSSI P R O F E S S I O N A L EI Electrical connection 230 V 1N 50 BC28A 110718 LEGEND 110718 ...

Reviews: