11. WARRANTY CONDITIONS 

Zantingh B.V. guarantees this Zantingh product for the installer under the following 
conditions. The installer guarantees this product to the user under the same 
conditions which are provided below. 

1.  The period of guarantee is valid as from the day of delivery on location.  

The guarantee has a fixed period of 12 months, based on the agreed sales 
price. 

2.  A recognized installer should install the system according to the applicable 

general and local standards and regulations based on the assembly and 
operation instructions provided by Zantingh. 

3.  The system may not be moved from the original location. 
4.  The guarantee becomes null and void if and when: 

  Defects of the system are not reported in writing to the installer and/or 

Zantingh B.V. immediately after having been discovered or these could 
reasonably be expected to have been discovered. 

  Defects are caused by errors, improper use or neglect by the installer 

and/or the user who has placed the order or his/her legal successor or 
caused by external causes. 

  During the period of guarantee a third party is requested to or 

implements changes to the system or when the user has done so 
without prior written consent by the authorized installer and/or Zantingh 
B.V. 

  During the period of guarantee the expert inspections and/or 

maintenance work are periodically not performed even though the 
equipment requires it. 

  Corrosion has been caused by polluted flue gas, to be determined by 

Zantingh B.V. 

  If after research is carried out, one or more of the above conditions 

were not taken into account and are the reason for any guarantee 
claim, the costs for the required research by Zantingh B.V. or third 
parties will be charged to the user. 

5.  The initial request based on the guarantee obligations described in this article 

should be submitted in writing to the installer within five working days after the 
error or defect has been observed or could reasonably have been observed. 

6.  The stipulations included in our general guarantee, sales and payment 

conditions, issued by the ORGALIME S 2012 “General conditions for the 
supply of mechanical, electrical and electronic products” are also applicable. 
Zantingh B.V. will not be liable for any consequential damage to the Zantingh 
system other than a defect covered by the guarantee as described above. 
Moreover, Zantingh B.V. will not be liable for any damage to income and/or 
loss of profit to the user of any nature whatsoever. 

7.  Any costs incurred by assembly or disassembly, travelling or accommodation 

expenses, constructional costs and such required to execute the terms of the 
guarantee are excluded from the terms of the guarantee. 

 
Any dispute between Zantingh B.V. and the buyer regarding a claim based on the 
guarantee will be resolved by an expert and independent authority if so desired. The 
parties agree to abide by the binding decision of said authority. 

Summary of Contents for RKB

Page 1: ...YOU CAN COUNT ON OUR EXPERTISE OPERATING AND INSTRUCTION MANUAL ZANTINGH FORCED GAS BURNER RKB LMV5 7 TOUCHSCREEN...

Page 2: ...s Page 1 INTRODUCTION 3 2 REGULATION 3 3 IMPORTANT NOTES 3 3 1 Maintenance 4 3 2 Instruction manual instructions 4 4 SYSTEM COMPONENTS 5 4 1 Burner component 5 4 2 Air fan component 5 4 3 Gas train 5...

Page 3: ...rtified heating or electrical installer should instal the product The instructions meet the applicable local standards and regulations Please contact your Zantingh representative or local service depa...

Page 4: ...end user s responsibility to ensure safety through annual maintenance work on the system according to applicable regulations To ensure the good operation of the heating system the boiler room has to b...

Page 5: ...the required combustion air This air fan has a directly coupled and balanced fan wheel The fan wheel is driven by an electromotor The air fan of a TR burner is directly connected to the air valve sect...

Page 6: ...ty device pos HD The HD pressure switch monitors the maximum burner boiler capacity and is mounted on the burner head to control the burner load by means of air pressure The settings of the pressure s...

Page 7: ...control panel includes a few switches and press button valves Fire on off switch Selector switch for load control with the following two options 1 Automatic modulated by load controller 4 External th...

Page 8: ...trol valve is positioned to the start low flame position The gas quantity control valve pos HR1 controlled by a servomotor is also positioned to the start low flame position The minimum air pressure i...

Page 9: ...ensures an easy steady start of the main flame It is only active when starting the flame The minimum gas pressure switch pos LD1 monitors the supply gas pressure continuously at the lowest applicable...

Page 10: ...ectronic fuel air ratio control PID temperature or pressure controller boiler controller load controller Variabel speedrive VSD module The system components are interconnected via a bus system Communi...

Page 11: ...rameter setting levels for the burner boiler manufacturer and heating engineer are password protected to prevent unauthorized access Basic settings that the plant operator can make on site do not requ...

Page 12: ...of current functioning level Operation Setpoint Setpoint W1 Act 80 Nw 80 Set the new value with the buttons and Press ENTER to confirm the value Change maximum load Operation User Max Load User MaxLo...

Page 13: ...refer to the annex AZL user interface H O M E R U N P h a s e 1 0 L M V 5 x H o m e R u n 1 0 S t a r t N o 1 2 3 4 5 6 F 0 5 1 A 0 2 4 0 4 3 S T A N D B Y P h a s e 1 2 S e t p o i n t 1 2 5 C A c t...

Page 14: ...N o 1 2 3 4 5 6 Example Safety loop open S a f e t y L o o p o p e n Lockout and error messages Example Immediate display of lockouts In the event lockout occurs the display alternates at 5 second in...

Page 15: ...of warnings the display alternates at 5 second intervals S l o p e t o o s t e e p Example Immediate display of start preventions In the event of start preventions the display alternates at 5 second i...

Page 16: ...7 touch screen The Siemens touch screen is a digital display with status of the connected circuits boiler safeties and burner status Home The main screen displays current information No safety relate...

Page 17: ...ing the boiler will give acces to the actual stystem status Green is functional red is fault error Pressing one of the menu items displays the error history Pressing the burner image in the Home scree...

Page 18: ...Page 18 LMV5000 EN202001V6 Setpoint Actuel Display of actual value and setpoint Log Display of error and error history Important error codes for diagnoses System Display of most important system data...

Page 19: ...ge 19 LMV5000 EN202001V6 Service Display of memo s remarks from engineers Trend Display of burner load flame signal and boiler temperature Combustion Display of boiler temperature actual load and outp...

Page 20: ...0 LMV5000 EN202001V6 Actuators Position of the actuators and related load in In outputs Display of which in or outputs are closed or open Also the burner phase error code Siemens LMV code will be disp...

Page 21: ...ximum load via the touch screen In the Home screen press on the red MAX LOAD block in the system image Press on Max Load Manual Preset and then on the the blue box next to it see image below Now set t...

Page 22: ...y pressure before the gas train by pressing the press button valve pos K2 under the manometer to read the current pressure on the manometer pos M Or check the manometer on the gas supply gas train Thi...

Page 23: ...previous item Check The air fan inlet Maximum temperature and or pressure The boiler is protected against high temperatures and or pressure A maximum thermostat or maximum pressostat device forms the...

Page 24: ...e flue gas valves The condensate drain and syphon under the condenser Autoflame system failure MM error If the Autoflame module display displays the Lock Out screen the MM has been triggered by an int...

Page 25: ...des Loose ignition cables Spark not in the correct position Refer to information on Earth mass No pilot flame Defect gas solenoid pos MK No combustible gas mixture does not ignite Pilot valve isn t de...

Page 26: ...ton on the switch panel door The burner will attempt to restart Note The maximum thermostat and the low water protection device may be mechanically locked The reset button on the safety device itself...

Page 27: ...let valve of the condenser on bypass 5 Check that every valve to the oil pump is open and whether the oil pump is filled with oil The complete system has to be filled with oil without any air If this...

Page 28: ...s inlet valve of the condenser to standard operation 6 Open shut off valve A1 7 Set the main switch on the burner control panel to ON WARNING Before starting the system check the furnace for oil If th...

Page 29: ...Page 29 LMV5000 EN202001V6...

Page 30: ...periodically not performed even though the equipment requires it Corrosion has been caused by polluted flue gas to be determined by Zantingh B V If after research is carried out one or more of the abo...

Page 31: ...ay or by any means be it electronically mechanically photocopy or otherwise without prior written consent from Zantingh B V Reprinting the document or any excerpt thereof is forbidden Changes errors a...

Page 32: ...Phone 31 0 297 219 100 Fax 31 0 297 219 199 E mail info zantingh com France Zantingh France SARL 95 rue F de Lesseps F 44150 Ancenis France Phone 33 0 240 83 94 30 Fax 33 0 240 83 96 72 E mail info za...

Reviews: