7
•
Press
the key to return to the main screen.
•
When the alarm ceases press the
Key to start the unit.
1.8. Alarm
list
Cod
Description
Type of restoring
A01
Environment probe failure
Manual
A05
Oil level alarm
Only display
A06
Air fi lter alarm
Only display
A07
Water temperature alarm
Manual
A08
Microdoor
Automatic
A09
Open door
Automatic
A10
Oil pressure alarm
Manual
A11
Maximumm pressostat alarm
Automatic
A12
High temperature alarm
Only display
A13
Low temperature alarm
Only display
A14
Thermal protection
Automatic
A15
Low battery level
Manual
A16
Start failed
Manual
A17
Alternator failure
Manual
A18
Pre-heat water probe failure
Only display
1.9. Alarm
description
A01 Enviroment probe failure alarm
This alarm causes the machine to stop permanently until the failure is repaired. To re-start the machine, you should
reset alarm following procedure described in the above-mentioned paragraph and press the on/off
key.
A04/11 Pressostat alarm
It occurs for a maximum or minimum pressostat intervention. The causes for the intervention of the maximum presso-
stat may be due to an inappropriate cleaning of the condenser or a slackening of the condenser fan belts, The inter-
vention of the minimum pressostat may be due to Freon leakage. The intervention produces the machine stop until
the alarm disappears.
A05 Oil level alarm
It is an only signalling alarm which does not affect the machine operation
A06 Air fi lter alarm
It is an only signalling alarm which does not affect the machine operation
A07 Water temperature alarm
It occurs when the radiator water temperature exceed the allowed value. It causes the diesel motor to stop. To re-
start the machine you should reset the alarm following the procedure described in the above-mentioned paragraph
and press the on/off
key.