61
If two cold rooms are present, the mask will appear:
To program the set point of the second cold room SP2, proceed as follows:
- Press key
: the cursor will start blinking under the present SP1 set point
value.
- Press the
key until the value relating to SP2 is highlighted.
- Press the UP/DOWN key to change such value.
- Press key
to store the defined value.
4.4 Turning on the refrigeration unit
Press the
button of the driver's cabin control to turn on the refrigeration unit.
If diesel operation is underway, engine startup is preceded by an acoustic signal.
A maximum of 5 startup attempts are possible after which, if the engine does not
start, an alarm is signaled.
The diesel engine always starts at maximum speed for a few seconds and then
decelerates to minimum speed, remaining in this condition for a time which is
determined by the engine's temperature.
When this phase has been concluded, the engine's RPM may be varied by
pressing the
key
(fig. 2)
.
If the refrigeration unit is to be used with the electric motor, first press the
but-
ton to stop the diesel engine.
Then connect the provided plug to the mains making sure that the voltage of the
mains is equal to that reported on the refrigerator's data plate.
The driver's cabin control is therefore automatically prepared for electric opera-
tion and the refrigerator unit may be turned on by pressing the
button. In this
case as well, startup of the electric motor will be preceded by an acoustic signal
lasting a few seconds.