Operating Manual ZX20T/TP/TC
ZX20TC:
LED
Color
State
Meaning
SYS
green
On
Bus module is ready
green/
yellow
Flashing
green/yellow Bus module is booting
yellow
On
-
Off
Device is deactivated or Bus module is
defective
ERR
red
Flashing
Invalid configuration
red
Single Flash Local failure: The slave device application
changed the EtherCAT status autonomously.
red
Double
Flash
Process data Watchdog Timeout
-
Off
No failure
RUN
green
Flashing
The device is in the Pre-Operational state
green
Single Flash The device is in the Safe-Operational state
green
On
The device is in the Operational state
-
Off
The device is in the INIT state
L/A IN
L/A OUT
green
On
Connected to Ethernet
green
Flashing
Active data exchange
green
Off
No Connection to Ethernet
L/A IN
L/A OUT
yellow
Off
This LED is not used.