PROGRAMMES ASSIGNING

PROGRAMME ADJUSTMENT

hEATING CURVE VALUES ADJUSTMENT

SENSOR ADAPTATION ADJUSTMENT

TEMPERATURE ADJUSTMENT

 

- assigning programme number to the particular day of the week, press OK to enter;

 Use cursors 

 to choose the day of the week to edit, and press OK to confirm;

 Use cursors 

 to choose the programme number to be assigned to a particular day of the 

week; press OK to enter days of the week window 

.

 

 - programmes review and adjustment, press OK to enter;

 Use cursors 

 to choose the required programme number to edit, press OK to confirm;

 When the programme number is chosen review its contents by means of cursors 

 the system presents data with 15 minutes difference. Press OK to edit the 

programme;

 Use cursors 

 to choose mode (temperature) that starts at 0:00, press OK to confirm;

 When the mode is chosen press cursors 

 to adjust the proper time of temperature operation, press OK to confirm; if the chosen mode (temperature) must 

operate till the end of the whole programme press the  , push button. It fills the whole programme memory with the previously chosen programme;

 If time is confirmed by OK command, use cursors 

 to choose the next mode to operate before the time previously adjusted (in certain point  ); press OK to 

confirm;

 Use cursors 

 to choose time for the adjusted temperature to operate - press the   push button to save the adjustments and to go to programme review.

Prog 0

Not editable programme: 

 

round-the-clock anti frozen temperature 

Prog 1

00:00 - 06:00 - economical temperature 

06:00 - 23:00 - comfort temperature 

 

23:00 - 00:00 - economical temperature 

Prog 2

00:00 - 06:00 - economical temperature 

06:00 - 08:00 - comfort temperature 

08:00 - 16:00 - output temperature 

16:00 - 23:00 - comfort temperature 

23:00 - 00:00 - economical temperature 

Prog 3

00:00 - 06:00 - economical temperature

 

06:00 - 08:00 - comfort temperature 

08:00 - 10:00 - output temperature 

10:00 - 12:00 - comfort temperature 

12:00 - 16:00 - output temperature 

16:00 - 23:00 - comfort temperature 

23:00 - 00:00 - economical temperature 

Prog 4

00:00 - 06:00 - comfort temperature 

06:00 - 13:00 - economical temperature 

13:00 - 15:00 - comfort temperature 

15:00 - 22:00 - economical temperature 

22:00 - 00:00 - comfort temperature 

Prog 5

Round-the-clock economical temperature 

Prog 6-9

Empty programmes 

 

- ready to be edited by a user - default 

adjusted comfort temperature 

t

[

h

]

t

[

h

]

t

[

h

]

t

[

h

]

t

[

h

]

t

[

h

]

t

[

h

]

temperature

There is an escape possibility from 

every  submenu  window  one  level 

higher in every moment of program-

ming  by  pressing    or    without 

saving the adjusments.

 

 (heating curve) - operation adjustment as a room temperature regulator 

or  temperature  regulator  with  reference  to  outer  temperature  (weather 

regulator), in accordance with pre-set heating curve values or individual curve 

points adjustments; press OK to enter;

 

 - room regulator operation adjustment;

 

 - weather regulator operation adjustment in accordance with pre-set 

heating curve types; 

 

 - weather regulator operation adjustment in accordance with individual 

values adjustments of heating curve points;

Window  : press OK to change heating curve type; use cursors 

 to adjust 

type - adjustment range: from 0,2 to 1,8  ; press OK to confirm;

Window  :  press  OK  to  adjust  individually  temperature  values  for  four  heat

-

ing  curve  points;    use  cursors 

  to  adjust  the  first  value  of  the  first 

point  of  the  heating  curve 

  which  describes  the  reference  tempera

-

ture  (e.g.  outside  a  building  in  case  of  weather  operation  mode);  press 

OK  to  edit  the  second  value  of  the  first  point  of  the  heating  curve 

 

 use cursors   to adjust the expected temperature values (e.g. central heating 

boiler temperature) which is obtained in case the reference temperature occurs 

; press OK to edit the first value (reference temperature) of the second point of 

the heating curve 

;   use cursors   to adjust the temperature for the second 

point; press OK to edit the expected temperature of the second point of the curve 

; repeat the same steps as for the first point; following OK commands confirm 

adjustments for the rest curve points till the second value of the fourth point 

 

 use cursors 

 to choose the required value and press OK to save adjust

-

ments and to go to a higher level.

Window  : press OK to adjust the regulator as a typical room regulator.

 

- sensor adaptation adjustment - when the user notices that the temperature measured by sensors 

is different from the real one, measure temperature correction can be done; press OK to edit;

 

 - press OK to change the adjusted value;   use cursors 

 to choose the required temperature 

correction from the range of - 4,5 °C ÷ +4,5 °C; press OK to confirm.

 

 - press OK to change the adjusted value;   use cursors 

 to choose the required temperature 

correction from the range of - 4,5 °C ÷ +4,5 °C; press OK to confirm.

There is an escape possibility from every submenu window one level higher in every moment of program-

ming by pressing   or   without saving the adjusments.

Individual exemplary heating curve

expected

 

temperature

 

(of a heater) [

o

C]

T2

reference temperature  (outer) [

o

C] T1

Heating curves for inner temperature of 20 

o

C

 

 - temperature adjustment; press OK to 

review and to edit; use cursors

 

 to choose 

temperature:

Window  : Antifreeze temperature - can not be 

changed by a user;

Window  :  Comfort  temperature  (day)  -  press 

OK to change the adjusted parameters; use cur

-

sors 

 

to choose the required temperature  ; 

press OK to confirm.

Window  :  Economical  temperature  (night)  - 

press  OK  to  change  the  adjusted  parameters; 

use cursors 

 to choose the required tempera

-

ture  ; press OK to confirm.

Window  :  Output  temperature  -  press  OK  to 

change the adjusted parameters; use cursors 

 to choose the required temperature  ; press OK to confirm.

Window  : Safety temperature - press OK to change the adjusted parameters; use cursors 

 to choose the required temperature; 

 - adjustment - stands for 

95 °C value  ; press OK to confirm.

CAUTION: 

If the regulator is in the weather mode, the adjusted temperature values constitute a point of curve shift. The basic heating curve is based on 20 °C 

comfort temperature. If the comfort temperature is adjusted to 25 °C the curve shifts to 5 °C up, however it goes 5 °C down if the comfort temperature is adjusted 

to 15 °C. The antifreeze temperature switches off the regulator and switches on protection mode against freezing.

heater

temperature

T2 [

o

C]

expected

temperature

(of a room)

[

o

C]

outer temperature T1 [

o

C]