FLUSH-MOUNTED ROLLER BLIND CONTROLLER SRP-05

 

USER MANUAL

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamel.com

, e-mail: [email protected]

plik: srp-05_inst_ext_gb | modyfikacja: 10.05.2023

INSTALLATION EXAMPLES

INSTALLATION

1. Disconnect the power supply circuit with 

a fuse, circuit breaker or switch discon-

nector connected to an appropriate cir-

cuit.

2. Check the de-energized condition on 

the power supply cables by means of 

the appropriate instrument.

3. Connect the cables to the appropriate 

controller terminals in line with the con-

nection scheme.

4. Place the SRP-05 device in the junction 

box.

5. Connect the power supply circuit and 

check for correct operation.

Roller blind group

Extended roller blind installation

WYGLĄD

FEATURES

TECHNICAL DATA

DESCRIPTION

• Intended for wire control of window 

roller blind, canopy, gate drives,

•  control of other devices powered by 12  

V DC or 24 V DC electric motors,

•  local and central control,

•  standalone operation or united in larger 

sections (grouping),

•  local control performed from the level 

or single or double roller blind switches,

•  central control performed from double 

roller blind switches only,

•  the roller blind is lockable in the closed 

or open position from the central input 

level,

• cooperation with alarm systems and 

auxiliary devices (e.g. a weather sta-

tion, an illuminance sensor, a precipita-

tion sensor, control timers),

•  release from the “+” line only,

•  the device is energy-saving, adapted to 

continuous operation,

•  comfort mode - upper and lower - sav-

ing the roller blind position,

• programmable maximum roller blind 

movement time.

The  SRP-05  flush-mounted  roller  blind 

controller is designed to control window 

roller blinds or other devices powered 

by direct current motors at 12 V or 24 V. 

Control can be local or central, using re-

turn roller blind switches. With local con-

trol, double and single switches must be 

used. With central control, only double 

switches can be used. In terms of func-

tionality, the controller can be used to pro-

gram two independent comfort settings 

(lower and upper) and maximum roller 

movement time. SRP-05 can operate as 

a standalone controller or can be united 

in larger sections. A special functionality 

of central control inputs can lock the roller 

blind in the closed or open position. The 

controller can thus cooperate with alarm 

systems and auxiliary devices, such as 

a weather station, an illuminance sen-

sor, a precipitation sensor, control timers. 

Pulses from the “+” line are the release 

signals.

Power terminals: +, -

Rated supply voltage: 12 ÷ 24 VDC

Rated power consumption:

standby:

 

0,053 W (at U

IN

=12 V DC)

 

0,21 W (at U

IN

=24 V DC)

work mode:

 

0,33 W (at U

IN

=12 V DC)

 

0,51 W (at U

IN

=24 V DC)

Maximum load: 6A

Control signal: short pulses from the “+” line

Optic signaling of roller blind movement: red LED

Default roller blind movement time: 120 s

Roller blind movement time programming: yes - from 1 s to 10 min.

Comfort position: yes - upper and lower

Time range for comfort modes: from 1 s to 10 min.

Local control terminals: LOCAL ( ), ( )

Central control terminals: CENTRAL ( ), ( )

Local control: double or single roller blind switches

Central control: double roller blind switches

Motor power terminals: M1, M2

Relay terminal parameters: 2NO 8A / 30 VDC (voltage contacts)

Number of connection terminals: 8

Section of connection cables: 0.2 ÷ 2.50 mm²

Operating temperature: -10 ÷ +55 °C

Working position: any

Housing fastening: Ø60 mm junction box

Housing protection rating: IP20 (PN-EN 60529)

Protection class: III

Contamination level: 2

Dimensions: 47.5 x 47.5 x 20 mm

Weight: 0.044 kg

Compliance with the following standards: PN-EN 60669, PN-EN 61000

DIMENSIONS

WARRANTY CARD

24-month commercial warranty

granted by the manufacturer

Seller’s stamp and signature with date of sale

1. ZAMEL Sp. z o.o. grants a 24-month warranty for the goods it sells.

2. The warranty granted by ZAMEL Sp. z o.o. does not cover:

a) mechanical damage caused by transport, loading/unloading or other circumstances,

b) any damage resulting from improper installation or use of the goods sold by ZAMEL Sp. z o.o.,

c) any damage resulting from any modifications made by the BUYER or any third party to the sold goods or to the equipment 

required for the proper functioning of the sold goods,

d) damage caused by any force majeure event or another fortuitous event beyond any reasonable control of ZAMEL Sp. z o.o.

3. The BUYER shall report all warranty claims in writing at the point of sale or to ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. will examine each warranty claim as regulated by the applicable provisions of the Polish law.

5. The form of warranty claim resolution, i.e. replacement, repair or refund of the price of purchase, shall be decided upon by 

ZAMEL Sp. z o.o.

6. This warranty does not exclude, limit or suspend any rights of the BUYER arising from the statutory or regulatory laws con-

cerning implied warranty for defects of sold goods.

Connect this product to a 

single-phase power system ac-

cording to applicable electrical 

and safety standards and regu-

lations. See this Manual for the 

wiring instructions. Installation, 

wiring  and  adjustment/setting  shall  only  be 

done by qualified electricians who have read 

and understood this User Manual and the 

functions of the product. Do not open or oth-

erwise disassemble the product housing; oth-

erwise the product warranty will be void and 

an electrocution hazard may occur. Prior to 

installing and wiring this product, make sure 

that the wiring to be connected is not live. The 

conditions and methods of transport, storage 

and operation of this product may affect its 

performance. Do not install the product if any 

of its components are missing, the product 

is damaged or deformed in any way. If any 

malfunctions are found, consult the manufac-

turer.

CAUTION

Do not dispose of this device with 

other waste! In order to avoid 

harmful effects on the environment 

and human health, the used device 

should be stored in designated 

areas. For this purpose, you can 

dispose of household waste free 

of charge and in any quantity to 

a collection point set up, as well 

as to the shop when you buy new 

equipment.

Terminals for connecting 

a 12 V DC or 24 V DC 

motor

Central control terminals 

(up/down)

Roller blind status

and programming status

signaling

Programming button

Local control terminals 

(up/down)

Input (supply) terminals

(+, -)

Power 

Supply

12 V DC

or

24 V DC

Power 

Supply

12 V DC

or

24 V DC

CENTRAL

 Roller blind123

CENTRAL

GROUP1

CENTRAL

GROUP123

CENTRAL

GROUP2

CENTRAL

GROUP3

LOCAL Roller blind1

LOCAL Roller blind1

LOCAL Roller blind3

LOCAL Roller blind5

LOCAL Roller blind2

LOCAL Roller blind2

LOCAL Roller blind4

LOCAL Roller blind6

LOCAL Roller blind3

GROUP1

GROUP3

GROUP2

Reviews: