8. FAQ
8.1 When the Coolant isn’t Circulating
(1) Check that the water pump is connected to the power.
(2) Verify that the pump is properly functioning. Remove the Reserator’s sink cover and
look inside to see if there is movement in the coolant. If there is none, contact the
distributor where you purchased the product.
(3) Make sure that the Reserator is installed correctly. It must be placed at the same level
as the PC, or slightly higher.
(4) Check if the coolant is flowing in the right direction.
(5) Inspect for any twists or folds in the silicone tubes of the system.
(6) Durning initial operation, the coolant may not properly circulate due to internal air
pressure. In this case, repeatedly turn the water pump on and off at a 10-second
interval and shake the silicone tubes to help get the air bubbles out. Once they are out
of the system the coolant should be circulating properly.
8.2 When There is a Leak at a Compression Fitting or Universal
Fitting Socket
(1) Turn off the system.
(2) Make sure the silicone tube is pushed all the way into the end of the Fitting Socket.
(3) Check to see that the tube is cut cleanly and squarely.
(4) Verify that the Fitting Cap has been screwed all the way into the end of the fitting Socket.