7. Separate the Reserator and Water Block
When moving this product to another location, or replacing the coolant or the water block,
separate the Reserator and the water block from the silicone tubes as shown below.
7.1 Moving the Reserator or Changing the Coolant
1) Turn off the PC’s power.
2) Using the tube clamps, as shown
in the diagram, insert the tubes in
to both sides of the Universal Fitting.
If the press clip isn’t properly tightened,
there may be leaks, so make sure
that the silicone tube is placed in
the middle of the clamp.
3) Turn clamp screw until it is tight.
4)Unscrew the Universal Fitting
Caps on the outside of the case
one by one. If you unscrew the
Fitting Socket Caps inside the
case, residual coolant may spill into
the case.
Computer Case
Clamp
Silicone
Tube
Universal Fitting
Silicone
Tube
Clamp
OUTSIDE
INSIDE
①
②
③
④
PCI Slot Hole
Clamp
IN Compression
Fitting
OUT Compression Fitting
Clamp
Flow Indicator
Press Clip