Use and programming
Coffee Pouring
On pressing the corresponding button
T1-T2-T3 or T4, the corresponding
delivery solenoid valves are activated for
the time necessary to obtain the required
amount of product as previously
programmed (volumetric check).
The delivery in progress may be
suspended before actually reaching the
desired programmed product quantity by
pressing button T5 Stop.
It is also possible to obtain simultaneous
coffee delivery from all the machine
groups.
Continuously Coffee Pouring
For continuous coffee measure delivery
press button T5 from the keyboard
corresponding to the group head which
one wishes to operate. Press again the
same button T5 to Stop.
Pre infusion
O u r s o f t w a r e p e r m i t s m e a s u r e
configuration so that the relative delivery
of the COFFEE measures through
volumetric control is
preceded by pre-infusion. Delivery of the
coffee measure after time 1 (ON) is
suspended for a time 2 (OFF) and is then
resumed for the completion of selection.
On pressing one of the volumetric control
measure buttons, the normal delivery
cycle is preceded by a short timed water
jet in order to dampen the coffee before
actual delivery stage.
This function ensures the optimum
extraction especially for espresso
coffees.
0
1
2
T1 T2 T3 T4 T5
T1 single espresso coffee
T2 double espresso coffee
T3 single long coffee
T4 double long coffee
T5 programming/continuos
and stop
T1
T2
T3
T4
T5
Boiler (filling) level time out
This alarm condition occurs whenever
the water level is too low or the level
probe remains uncovered. In such a case
all the buttons are lit.
The filling stage is automatically engaged
and to cancel the alarm conditions switch
the machine off and then on again.
Alarm conditions all buttons lit
T5
T4
T3
T2
T1