background image

CONFIDENTIAL                                

DOC-USR-0126-03 

Z3 Technology, LLC 

 100 N. 8th St. STE 250 

 Lincoln, NE 68508-1369 USA 

 +1.402.323.0702 

 

 

 

 

 

Figure 2 Side view of assembled Z3Cam, RS-485 connector J5 circled in red 

 

2.1

 

RS-485 control is available from the connector PCB at header J5. 

 

The RS485 header uses 1.25mm spacing.   
The exact part number used for J5 is 

Hirose DF13-4P-1.25DSA

.   

The recommended mating part is the 

Hirose DF13-4S-1.25C

 shell plus the appropriate pins. 

 
On J

5, the RS485 ”A” signal is on pin 1 and “B” on pin 2 

 

(see  Figure). 

 

Summary of Contents for Z3CAM

Page 1: ...y LLC All rights reserved This document contains proprietary and confidential information of Z3 Technology LLC Z3 This document may not be used reproduced disclosed or disseminated to anyone without t...

Page 2: ...3 Technology LLC 100 N 8th St STE 250 Lincoln NE 68508 1369 USA 1 402 323 0702 Revision History Version Date Change Note Author 2 12f 08 28 2017 Original Document JW 2 13 11 15 2017 Typo fixes CF 2 13...

Page 3: ...50 Lincoln NE 68508 1369 USA 1 402 323 0702 TABLE OF CONTENTS 1 0 GENERAL DESCRIPTION 5 2 0 HARDWARE SETUP 5 3 0 Using ONVIF RS 485 Pelco D PTZ Controls 8 4 0 Using RS 232 port instead of RS 485 for c...

Page 4: ...0702 LIST OF FIGURES Figure 1 RS 485 connector J5 on HEXX DCK FV2K DCK electronics 5 Figure 2 Side view of assembled Z3Cam RS 485 connector J5 circled in red 6 Figure 3 Cable insertion precautions fr...

Page 5: ...N In the security market there are many different schemes for Pan Tilt Zoom PTZ control This App Notes describes various scenarios from using standard ONVIF controls for Pelco D commands on RS 485 to...

Page 6: ...S 485 connector J5 circled in red 2 1 RS 485 control is available from the connector PCB at header J5 The RS485 header uses 1 25mm spacing The exact part number used for J5 is Hirose DF13 4P 1 25DSA T...

Page 7: ...ince the case metalwork does not have a hole for J5 on the rear panel it is recommended to install the mating shell using tweezers and route the wires out where possible The mating shell should be plu...

Page 8: ...m or device connected to the RS 485 port 2 If you have not already done so install the Com2TCP application onto your PC Windows 7 is recommended For Windows 8 or 10 verify you are using v1 4 6 Com2TCP...

Page 9: ...COM port selected will now redirect data to the Z3 Unit Note If the camera is rebooted or power cycled you will need to reconnect COM2TCP on your PC COM2TCP does not automatically detect the dropped...

Page 10: ...correct you can revert the settings to the original and try again by running fw_setenv bootargs_misc cat tmp orig txt fw_printenv bootargs_misc 2 Change settings in Term tab on web page to use RS 232...

Page 11: ...the vi editor on the target bin sh mknod dev console c 5 1 mknod dev ttyAMA0 c 204 64 mknod dev ttyAMA1 c 204 65 mknod dev ttyS000 c 204 64 mknod dev ttyS000 c 4 1 mknod dev null c 1 3 5 0 INTEGRATING...

Reviews: