CONFIDENTIAL
DOC-USR-0206-01
8
____________________________________________________________________________________
Z3 Technology, LLC
♦
100 N. 8th St. STE 250
♦
Lincoln, NE 68508-1369 USA
♦
+1.402.323.0702
7.5
No hot-plugging of cards
The MVE-SPEC rack and blades are
NOT hot pluggable
. Hot plugging blades can cause permanent
damage to the slot connectors. Note: hot swapping Blades will VOID warranty on MVE-SPEC and
Blades.
8.0
SPECIFICATIONS
▪
Form Factor: Standard 19-inch rack, 1 RU, 355 mm deep
▪
Power Input: 90-264 VAC at 47-63 HZ, 125-370 VDC with IEC 60320-1 C14 compliant jack
▪
Inrush current: Typ. 35A/115VAC, 70A/230VAC
▪
Maximum power consumption: 250W
▪
Sixteen 2.5mm barrel jacks for serial communication, four per slot
▪
Operating temperature: 0°C to +50°C, 20-80% RH non-condensing
▪
Storage temperature: -10°C to +80°C, 20-80% RH non-condensing
▪
Card size: 90x200 mm
When contacting Z3 Support for additional support, please click the
“download device logs” button in the GUI at the time the problem occurs and
send the resulting .gz file, along with screenshots of the all running channels and the Status tab to Z3 Technology.
Z3 Technology’s Express Limited Warranty will be void if the l
abel on the hardware bearing the Serial Number is removed, tampered with or
defaced. You can view Z3 Technology’s full hardware warranty at
http://z3technology.com/Support/ZEUS-HW-Warranty.html