Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt
the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128
…
255 the value sent in the application shall be the desired value minus 256. For example: to set a parameter to
200
it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value the same logic
applies: Values greater than 32768 may needed to be given as negative values too.
Command to Control Group №1 (association group 2) (Parameter Number 10, Parameter Size 1)
This parameter defines the command to be sent to devices of control group №1 when the related button is
pressed (association group 2)
Value
Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
Command to Control Group №2 (association group 3) (Parameter Number 11, Parameter Size 1)
This parameter defines the command to be sent to devices of control group №2 when the related button is
pressed (association group 3)
Value
Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
Command to Control Group №3 (association group 4) (Parameter Number 12, Parameter Size 1)
This parameter defines the command to be sent to devices of control group №3 when the related button is
pressed (association group 4)