Operation Flow:
Step 1.
The power cord is connected. At this point, the LCD display is powered off.
Motor, fan and hot rod are kept off.
Step 2.
Press power button,
which powers the grill on. LCD display is till turned off
and press the start button
the grill will begin its Startup Cycle.
Motor, fan and hot rod will automatically activate during Startup Cycle.
The whole Startup process takes 6 minutes. If the grill is successfully ignited, it would
automatically begin it’s Running Cycle.
STARTUP -
After the initial Startup Cycle begins, the temperature dial can be adjusted
without resetting the Startup Cycle.
1. The hot rod heats up within 6 minutes.
2. The auger motor runs in algorithm of PID.
3. The fan is always on.
At the end of the Startup Cycle, the RTD sensor would automatically run a temperature
check inside of the grill. The startup process is successful if the temperature is increased by
more than 40F or the temperature exceeds 120F. If the grill fails the Startup process, it will
automatically restart from step 1.
The grill will attempt the startup cycle a total of 4 times. If any of the following temperature
changes accurse: grill temperature is increased by 40F or internal temperature reaches
120F the grill will start its Running Cycle. If the grill fails to start the Running Cycle after 4
attempts, the display will show “Er2”.
The auger motor, fan and hot rod will shut down automatically.
Step 3.
Use the knob
to set desired temperature of the grill. At the end of the Startup
Cycle, the grill will automatically begin its Running Cycle.
The motor, fan and hot rod are will run according to set temperature.
Running Cycle
- Fan is always on, auger is running in algorithm of PID according to set
temperature, hot rod is deactivated)
The display will show the actual temperature inside the grill and the probe temperature in P1
and/or P2 if probes are connected at all times.