12
4.POSITIONING THE CHAMBER ON THE BODY FRAME
Lift up the Chamber (1) on the Body Frame (3). Make sure that the Chamber (1) is inside the
left and right plate of the Frame (3). Align the Chamber holes with the plate holes and secure
with Bolt (B).
5.Installation instructions for RTD Temperature Probe
1.Remove the screws from the left plate of the grill chamber.
2.Use the screws through the RTD Temperature Probe and fix on the left plate of the grill
chamber.
3.The distance between the RTD Temperature Probe and the left panel of the grill chamber
should be kept about 14mm, otherwise the RTD Temperature Probe effect will be affected.