13
Version 1.0.0
Using Battery*
1. Mount V-Mount battery onto V-Mount Battery Plate [35] of the PSU, one on each side;
2. Push gently downwards and lock into position;
3. Connect one end of the Battery Power Cable (4-Pin) [57] to the Battery Power Output [40] of the
PSU, the other end to the Battery Input [18] of the Main Unit;
4. To unmount the battery, press and hold the Quick Release Button [36] of the PSU and lift the
battery upward. Press and hold the safety flake on the Battery Power Output [40] of the PSU to
disconnect the Battery Power Cable [57]. Press and hold the safety lock of the Battery Power
Cable [57] plug to pull it out from the Main Unit.
1
2
3
4
* Only 14.8V V-Mount batteries can be used. Not included in the standard package.
Graphic
:
Battery Power Supply Connection
ZOLAR™ Toliman 30C User Manual