YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
Page 109
NJEX 7300G ver. 08-2018
Appendix B: N-300 Modbus Specifications
Boolean Registers
Control Functions,
Continued
Address Access
Description
00007
............
Read/Write .............. Local/Remote Load Cycle Control (toggle) (Liquid System Only)
00008
............
Read/Write .............. Proportional to Time/Flow mode (toggle)
00009
............
Read/Write .............. Save Parameters to EEPROM
00010
............
Read/Write .............. Remote Inhibit / Run the N-300 (toggle)
00011 ............ Read/Write .............. Local/Remote Inhibit Control (toggle)
Status Functions
The status functions available via Modbus are listed below. The registers are accessed using Modbus func-
tion 1. Status labeled with an “L” after the Access types are latching type status. A latching status provides a
“since the last read” type status where a set condition will hold it’s state until a read of that particular register
was made by the master device. Once a read is made, the status will reflect the current state.
Address
Access
Description
00101
............
Read Only ............... System Stopped (0) / Running (1)
00102
............
Read Only ............... Verometer Not-Filling (0) / Filling (1)
00103
............
Read Only ............... Not in Standby (0) / Standby (1)
00104
............
Read Only ............... Memory Module Invalid (0) / Valid (1)
00105
............
Read Only ............... Z-65 Backup Disabled (0) / Enabled (1)
00106
............
Read Only ............... English (0) / Metric (1)
00107
............
Read Only ............... Proportional to Time (0) / Proportional to Flow (1)
00108
............
Read Only ............... Analog (0) / Pulse (1)
00109 ............ Read Only ...............
Linear (0) / Non-Linear (1) or Pulses/Sec (0) / Pulses/Min (1)<-Gas PPMV(1)<-LPG
00110 ............ Read Only ............... Gas (0) / Liquid (1)
00111 ............ Read Only (L) ......... No Power-Up (0) / Power-Up (1) since last coil read
00112 ............ Read Only ............... Odorant Tank Low Alarm Enabled (0) / Disabled (1)
00113 ............ Read Only ............... Signal Alarms Enabled (0) / Disabled (1)
00114 ............ Read Only ............... Verometer Alarms Enabled (0) / Disabled (1)
00115 ............ Read Only ............... Pump Alarms Enabled (0) / Disabled (1)
00116 ............ Read Only ............... Battery Alarm Enabled (0) / Disabled (1)
00117 ............ Read Only (L) ......... No Parm Change (0) / Parm Change (1) since last coil read
00118 ............ Read Only .............. Normal (0) / No Flow Standby (1)