DynaPak 2010N Version 05302001 ATEX Rev.
YZ Systems, Inc. • 3101 Pollok Drive • Conroe, Texas • USA • 77303 • P: 936.788.5593 • F: 936.788.5720
23
E. This will cause all six digits to become active on
the stroke counter. Depress the reset. The stroke
counter should increment 000000, 111111, etc.,
up to 999999 each time the solenoid fires. When
the counter display reads 999999, the test is
complete.
Note: When the test is complete,
move the jumper back to the
factory position (far left position).
12.4 Timer Range Setting
A. There are two Z-65 models: the Z-65/6.1 and
Z-65/6.03. Each Z-65 timer has two ranges for the
timer setting dials.
1. Z-65/6.1 Range Setting:
a. xx minutes: set the configuration jumper to the
far left position (factory setting).
b. x.x minutes: set the configuration jumper to the
center position.
Note: To obtain maximum battery life, choose the
longest solenoid stroke rate possible.
factory positioned
for 1 - 99 counts (xx)
Jumper switch location
Jumper switch location
for .1 - 9.9 counts (x.x)
Mutual
System
Approved
Factory
Mutual
System
Approved
Factory
12. Troubleshooting - Timer Mode