Battery Installation

1.Thread thinner end of the lanyard through the hanging hole.
2.Thread thicker end of the lanyard through the threaded end 

before pulling it tightly.
3.Install as the figures show. (See Figure )

Lanyard Installation

1.Pull the battery cover horizontally.
2.Put two AAA batteries into battery cassette in right polarities and push the 

cover back.
Notes: Battery polarities must be correct. Otherwise, damage might occur to device. 
Please put or remove batteries in right order, or it will damage  the device bracket. 
Please remove the battery if the oximeter is not used for long time.
3.Install as the figures show. (See Figure)

Remove the battery from the product if it is not required for extended

Product Operation Steps

1.Install two AAA batteries into battery cassette before closing the cover.

2.Nip the clamp as diagram to the largest.(See Figure )

3.Plug one finger into rubber hole of the Oximeter (it is best to plug the finger 

thoroughly) before releasing the clamp.

4.Do not tremble while the oximeter is working. It's better that the whole body be 

in still status.

Note: For normal use after long interruptions, refer to the product operation steps.

5.Read corresponding data from display screen.

7

8

1. Determination of Oxygen Saturation Accuracy 
The claimed oxygen saturation is supported by coverage of the entire range of clinical research 
measurements. 

2.Data Collection
In the clinical test process, data points are recorded with comparable density in the entire claimed 
range.
3. Data Analysis
For each claimed range, the oxygen saturation accuracy of the Pulse Oximeter should be represented 
in the form of mean root square of the difference between the measured values of oxygen saturation 
and the reference value. The formula is as follows:
A

rms

: accuracy. 

n: test sample quantity. 
SpO

2i

 : measured value of pulse oxygen saturation during the first measurement using the finger pulse 

Oximeter. 
S

Ri

: reference value of pulse oxygen saturation during the ith measurement using the carbon-monox-

ide-blood-gas analyzer.
4. Characteristics of Population under Clinical Research 
The group of healthy adult volunteers for the study consisted of 12 subjects - 4 women and 8 men, The 
ages ranged from 18 to 50 years. The subject weights ranged from 48 to 90kg. The subject Height 
ranged from 160 to 182cm. The Skin tones included in the study were as follows: 3 subjects with dark 

Product Operation Scope

The YUWELL

®

 Finger Pulse Oximeter is designed for fingers(not thumb) between 0.3 and 0.9 

inch (0.8-2.3cm) thick. And the finger shall be inserted into the sensor position which is in the 
middle of the device. 
The Finger Pulse Oximeter is NOT design for newborns and infants.

Product Properties

1.Operation of the product is simple and convenient.
2.The product is small in size, light in weight and portable.
3.The product can operate continuously for 17 hours with two brand new AAA batteries. (The operation 
time may vary due to the different performance of batteries) 
4.Low voltage prompt will appear on the display when the battery voltage is lower than the minimum 
value of normal working voltage range.
5.The product will automatically shut down when there is no signal detected for about eight seconds.

periods of time in order to avoid damage to the oximeter resulting from a leaking battery.
       Do not use the new batteries with the old ones. Alkaline battery of long service is recommended, 

and do not use rechargeable batteries. 

pigmentation, 5 subject with very light pigmentation. 
The remaining subjects with light (medium) skin 
tones of Asian origins.
5.Graphical Plot of SaO

2

 versus error (SpO

2

 - SaO

2

)

6.The technology used in Finger Pulse Oximeter has 
been verified with accuracy when there is no motion 
via human blood studies on healthy volunteers of 
both male and female with light to dark pigmented 
skin in induced hypoxia studies in the range of 
70%-100% SpO

2

 against a laboratory co-oximeter.

7.The technology used in Finger Pulse Oximeter has 
been verified with the pulse rate accuracy of 
25-250bpm range in the bench top test against 

Summary of Contents for YX102

Page 1: ...ue to the limited size of the label the font is too small please put it at a suitable location for viewing All specifications and product configurations are subject to change without notification YUWE...

Page 2: ...ous oxide to avoid the risk of explosion 15 Caution When using this product you only need to fix it on your fingers Excessive pressure on your fingers may cause skin damage 16 Caution The maximum skin...

Page 3: ...ight can be focused onto human nail tip through perspective clamp finger type sensor Then measured signal can be obtained by a photosensitive element information acquired through which will be shown d...

Page 4: ...cy The claimed oxygen saturation is supported by coverage of the entire range of clinical research measurements Indication for Use Intended use The YUWELL Finger Pulse Oximeter is a kind of non invasi...

Page 5: ...monox ide blood gas analyzer 4 Characteristics of Population under Clinical Research The group of healthy adult volunteers for the study consisted of 12 subjects 4 women and 8 men The ages ranged fro...

Page 6: ...ell should be maintained from dust pollution use a soft cloth or lint free cleaning agent with the sponge to wipe Make sure no liquid will enter into the equipment Disinfecting The recommended disinfe...

Page 7: ...aration Radiated Emission Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Compliance Group 1 Class B Table 1 For all ME EQUIPMENT and ME SYSTEMS RF emissions CISPR 11 Emissions test Result...

Page 8: ...resent actual modulation it would be worst case 1700 1990 2400 2570 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 1720 1845 1970 2450 Pulse m...

Reviews: