System and Packaging

 

 

 

Batch code

 

Date of manufacture

 

 

Catalog number

 

Not made with natural rubber latex

 

 

 

+60

 

+140℉

 
 

 

-20

 

-4℉

 

Temperature limitation

 

 

90

 

 
 
 

10

 

Humidity limitation

 

Manufacturer

 

 

Authorized Representative in the European Community

 

 

Medical Device

 

 

Use-by date

 

Consult instructions for use

 

Single Patient - multiple use

 

Caution, consult accompanying documents.

 

Indicates a Warning or Caution and alerts you to a possible injury 
or  explains  special  measures  for  the  safe  and  effective  use of  the 
device.

 

CE Mark

 

Symbols

 

Summary of Contents for Breathwear Series

Page 1: ...User Manual Breathwear Series NasalMask YN 02...

Page 2: ......

Page 3: ...used In either case it is up to the doctor to decide whether or not to use the mask These diseases include y Recent eye surgery or dry eyes y Glaucoma y Hiatal hernia y Impaired cardiac sphincter func...

Page 4: ...three hours before using the mask This mask is not recommended if the patient is taking a prescription drug that may cause vomiting y This mask should not be used on patients who are uncooperative ob...

Page 5: ...y Stop using the mask and consult your physician or sleep therapist if you have ANY adverse reaction to the use of the mask y Refer to your flow generator manual for details on settings and operationa...

Page 6: ...asks some rebreathing may occur at low CPAP pressures y Remove all packaging before using the mask Vent Elbow Swivel Frame assembly Forehead support Frame Clip Cushion Upper headgear straps Lower head...

Page 7: ...5 Headgear...

Page 8: ...6 Use a standard conical connector if pressure readings and or supplemental oxygen are required 4 3 2 1 Fitting...

Page 9: ...he mask fit well 5 Undo the fastening tabs on the lower headgear straps Pull the straps evenly until the mask is stable and comfortable Reattach the fastening tabs 6 Your mask and headgear should be p...

Page 10: ...y be incurred and the re installation will become more difficult 1 Detach the air tubing Unclip the lower headgear clips and unhook the upper headgear straps 2 Gently separate the cushion from the fra...

Page 11: ...se damage and reduce the life of the product y Exposing any part of the system or tubing to direct sunlight or heat may cause deterioration y Do not use dishwasher to wash this mask y Do not the mask...

Page 12: ...nent is apparent cracking crazing tears etc the mask component should be discarded and replaced CAUTIONS The mask is for single patient use in the hospital or institutional environment If the mask get...

Page 13: ...tructions in Cleaning the Mask at Home Pressure Flow Curve 70 60 50 Flow Rate L min 40 30 20 10 4 8 12 16 20 25 30 Mask Pressure cmH2O Dead Space Information Dead space is the empty volume of the mask...

Page 14: ...nditions Operating temperature 5 Cto 40 C 41 F to 104 F Operating humidity 10 90 relative humidity non condensing Storage and transport 20 Cto 60 C 4 F to 140 F Storage and transport humidity 10 90 re...

Page 15: ...limitation Manufacturer Authorized Representative in the European Community Medical Device Use by date Consult instructions for use Single Patient multiple use Caution consult accompanying documents I...

Page 16: ...90 days from the date of purchase by the initial consumer This warranty does not cover damage caused by accident misuse abuse negligence alteration failure to use or maintain the Product under condit...

Page 17: ......

Page 18: ...9 Jinfeng Road Suzhou Science Technology Town 215163 Suzhou Jiangsu PRC Tel 86 512 67373001 web address www yuyue com cn Metrax GmbH Rheinwaldstr 22 D 78628 Rottweil Germany Tel 49 741 257 0 49 741 2...

Reviews: