Jermei Ultrasonic Nebulizer 

JM-06801 

User Manual 

Summary of Contents for JM-06801

Page 1: ...Jermei Ultrasonic Nebulizer JM 06801 User Manual...

Page 2: ...formation 2 2 Features and Applications 3 3 Parts 4 4 User guide step by step 4 5 5 Section 2 General Information 9 1 Symbols 9 2 Safety cautions 9 3 Maintenance 11 4 5 Issue diagnosis and debugging W...

Page 3: ...n Permit SN Made by Shenzhen Jermei Medical Device Technology Co Ltd Sold by Jermei Internalization Trading LLC Official website https jermei net User guide print date Our products could be used for m...

Page 4: ...ning for 15 minutes no signal input or output part No permanent installation device 2 6 Running Environment Temperature 5 C 40 C Relative humidity 90 Atmosphere pressure 70kpa 106kpa Power 220VAC 50 6...

Page 5: ...g mechanical vibration impact or strong magnetic field 3 1 Features Portable Cold and warm mist switch High low mist volume switch Detachable water tank or strong magnetic field 4 1 List of parts 3 Fe...

Page 6: ...wet hands Before every use Detach and wash the water tank Detach and wash the mask Replace the essential oil pill Fill the tank with filtered or purified drinking water Connect the power cord to the n...

Page 7: ...it to pill holder at the nozzle 3 Choose cold mist or warm mist mode A Push Cold mist button once to turn on cold mist mode the button circle and water tank will show blue light Low mist volume light...

Page 8: ...Push Warm mist button twice high mist volume light will be one and warm mist will be sprayed consistently C Push Warm mist button again to turn it off Mint essential oil pill Notes Load the essential...

Page 9: ...cs 8 Do not pour any liquid on the pill 5 4 Maintenance 5 5 Alarm indication It is very important to clean and sanitize the nebulizer regularly keep it performing Important note The remaining water in...

Page 10: ...Mist Button Warm Mist Button The battery needs to be charged when the light is on Warning Please save and read following instructions It might cause electric shock fire or severe injury if violating a...

Page 11: ...g 12 Please do not use detergent wash any part filled with water which could interfere with nebulizer s output Use plain vinegar to wash the tank instead 13 Lift the nebulizer with its bottom instead...

Page 12: ...nebuli zer by following above step 1 2 3 4 4 Make sure each part completely dry 4 5 Put the nebulizer in a dry and cool place within the bag 3 Clean the water tank Don t put the water tank in washer...

Page 13: ...lly charged Soak the water tank in the water with plain vinegar mixed for 15 minutes Then put the empty tank in a cool and dry place for 12 hours Try to tighten the 4 screws on the back of the water t...

Page 14: ...ce Notice The warranty covers only claims for material and manufacturing defects but not for transport damage This product is for domestic use only and is not intended for commercial use The warranty...

Page 15: ......

Page 16: ......

Page 17: ......