Revised 04/04/08
ALLURE ELECTRONIC Install & Ops Apr08
Page 7 of 23
N.B. Diagram is for
INDOOR installations,
NTS for illustration purposes
(930 model uses 200mm flue, 250mm liner)
CONDITIONS FOR FLUES.
1. The Flue Shall Extend to:
a) In the case of a Pitched roof, Not less than 600 mm above the Highest Point of the
Roof.
b) In the case of a Flat roof, (ie. With a Pitch of less than 30°) not less than 1500 mm
above the Highest Point of the Roof.
c) In any case the length of the Flue shall be not less than 3.6 metres from the Top of
the Appliance Flue Spigot.
2. Minimum Total Flue Length = 3.6 metres
3. Flue must be 1.2 metres high before any Lateral is fitted.
4. Any Lateral run in a Flue shall be:
a) No more than 1.0 metre in the horizontal plane
b) Not be less than 45 degrees above the horizontal plane.
TYPICAL FLUE INSTALLATION
(FREESTANDING)