Revised 04/04/08
ALLURE ELECTRONIC Install & Ops Apr08
Page 11 of 23
GAS PRESSURE TESTING
(cont)
(Fig 5)
NOTE: Modulator pressure adjustments are factory set. It is not expected that adjustment will be
required during installation.
Setting Pressures:
(Fig 4 and 5)
MAXIMUM PRESSURE:
The modulator is adjusted by screwing IN Brass Nut “ 5 “ to increase
the outlet pressure and screwing OUT to decrease it.
MIMIMUM PRESSURE:
Keep Brass Nut “5” stationary, screw IN the Red Plastic Screw “4” to
increase the pressure and screw it OUT to decrease the pressure.
Pilot Outlet
4
5