Revised 27/05/10
ALLURE Outdoor Install May2010
Page 4 of 17
DIMENSIONS and CLEARANCES
Diagrams on the following pages are not to scale. All measurements are in millimetres.
The Yunca Allure Outdoor flued gas fire is to be installed with clearances equal to, or greater
than, those recommended on the following pages, and must comply with
NZS 5261:2003/AG601
ZERO CLEARANCE FIREBOX
MODEL
F
G
H
J
K
L
X
FLUE DIA
INNER / OUTER
730
400
360
235
590
670
900
740
150/200
930
400
360
235
590
670 1100 940
200/250
Also available is a Bottom Fascia Strip for each model. This strip (85mm high)
is fitted below a regular three-sided fascia for a “picture frame” look
.
TIMBER FRAMES
Should a timber frameout be used
outdoors, then the following is required.
Heat resistant board, 500mm high and the
same width as the lining cutout, is required
above the fascia.
Note:
Framing minimum width from the side
of the zero clearance firebox to the side wall
is 130mm (on each side), i.e. the minimum
width of the chimney chase shall be
Dimension “B” + Dimension “C” + 260mm.
This is to ensure air circulation around the
appliance and avoid heat damage to wall
coverings. Installation must comply with
NZS5261:2003/AG601
MODEL
A
B
C
D
730
80
25
790
620
930
80
25
1000
620