background image

 

Regular maintenance of the scope will help keep the device free from malfunctions and 
untimely wearing of parts and connectors. 

 

Failure to observe these warnings will void the manufacturer's warranty

.  

 

 

BATTERY INSTALLATION 
 

 

Turn the knob of the battery compartment cover 90º counterclockwise (1) to match the red dot 
on the knob with the red dot on the battery compartment cover.  

 

Remove the cover by raising it by its lug.    

 

Slide in two 

АА

 batteries so that the “+” and “-” match the polarity on the inner side of the 

cover; rechargeable AA batteries may be used. 

 

Close the cover of the battery compartment cover and turn the knob of the cover 90º 
clockwise. 

 

 

 
OPERATING THE SENTINEL G2+ 
 

WARNING: It is strongly recommended to test and operate the Sentinel G2+ in dark 

conditions or at night time. 

 

 

Install the batteries according to the directions in the section entitled “BATTERY 
INSTALLATION”. 

 

Enter a dark environment.  

 

Remove the objective lens cap by sliding it up on top of the objective lens (2). 

 

Activate the scope by turning the power switch to the “ON” position (3). 

 

Select the color of the reticle, green or red, by pushing the button (5) until its clicking position.    

 

Adjust the reticle brightness by rotating the switch (4). 

 

Please select an object of observation at a distance of approximately 100 meters (about 110 
yards) away.    

 

Set up the objective focus ring knob (6) to be aligned with the mark "100". 

 

Focus on the selected object by rotating the eyepiece ring (7). If needed, turn on the IR 
illuminator (8) by turning the switcher (3) to the “IR” position.  

 

Rotate the IR illuminator lens ring - by doing so it moves forwards and backwards - until the IR 
illuminator beam is focused (picture quality turns worse if the luminance level is excessive). If 

Summary of Contents for 26125T

Page 1: ...djustment IPX4 rating against water intrusion Precision internal windage elevation adjustment Ergonomic design Quick power up Vertical positioning of the battery ensures uninterrupted power supply whe...

Page 2: ...r use with cartridges producing recoil rating higher than 6000 joules or calibers in excess of 9 375 The manufacturer s warranty will be voided if damage is caused by caliber cartridges greater than 9...

Page 3: ...ions or at night time Install the batteries according to the directions in the section entitled BATTERY INSTALLATION Enter a dark environment Remove the objective lens cap by sliding it up on top of t...

Page 4: ...n the ON or OFF position the IR illuminator will not have any effect in a lighted environment Note The sighting of the scope should be performed under the same environmental and temperature conditions...

Page 5: ...cle the target is 25 meters 27 yards away Please see a drawing below VERTICAL SCALE The four short horizontal bars are located on the main vertical line If a 0 35 meter 13 7 inch high target fits betw...

Page 6: ...Range in Meters Object s Width or Height in Mils Example 1 33 yards x 1000 2 5 mils 532 Yards When making windage elevation adjustments please note that one click of the riflescope s adjustment equals...

Page 7: ...ply solution to a clean dry cloth and then proceed to clean the lens WARNING Please use extreme caution when handling hazardous substances such as alcohol THE SENTINEL G2 MAGNIFIER LENS 2 5x50 The NVR...

Page 8: ...g it in a warm environment for 4 hours Total battery charge is less than 2 0V Install fresh batteries With a crisp reticle image the image of the target at least 30m away is blurred Luminance level in...

Page 9: ...cording to the instructions in the OPERATING THE SENTINEL G2 section and check the eyepiece and objective lens condition if necessary clean the lenses of dirt dust condensation frost etc to prevent fo...

Reviews: