TECHNICAL PARAMETERS

Item

Engine Model

Engine Type

Displacement (cc)

Gas Distribution Mode

Cooling Mode

Rated Speed (RPM)

Starting Method

Fuel Tank Volume (L)

Fuel Type and Grade

Lubricating Oil Capacity (L)

Lubricating Oil Model

Forced cooling wind

Vehicle-use unleaded gasoline

Noise dB (at 7m)(25% load)

Rated Power (kW)

Max. Power (kW)

Rated Voltage (V)

Rated Frequency (Hz)

Rated Power Factor

Phase Number

Run Time @ 25% (h)

Overall Dimension (mm)

Net Weight (kg)

YS4000i

Stroke x Bore (mm)

164F

/

P

145

OHV

4600

Recoil start

3.6

SAE

 

10W

/

30

0

.

45

62

3.0

3.3

230

50

1

Single phase

21.5

64x45

6

485×285×455

4-stroke

Fuel Consumption Rate
(25% load)(L/h)

THD

Fuel Consumption Rate
(100% load)(L/h)

0.85

1.9

3%

Valve Clearance

Input valve

0.03~0.08mm, Output valve

0.03~0.08mm

Summary of Contents for YS4000i

Page 1: ...mportant information regarding safety Operation maintenance and storage of this product Before use read carefully and understand all cautions warnings instructions and product labels Failure to do so...

Page 2: ...s only Moreover because of our continuous product improvement policy we may modify information illustrations and or speci cations to explain and or exemplify a product service or maintenance improveme...

Page 3: ...2 USING THE GENERATOR 13 1 Service environment of the generator 13 2 Generator wiring 13 3 Generator grounding 14 SERVICE AND MAINTENANCE 15 1 Spark plug inspection 16 2 Adjustment of the carburetor 1...

Page 4: ...extremely serious injury Failure to follow the instruction will result in being in peril of your life or very serious injury Failure to follow the instruction will result in minor injury Failure to f...

Page 5: ...and familiarize yourself with the safe operation procedures of the generator Please do not use indoors Please do not use in humid environment Please do not connect it to household appliances directly...

Page 6: ...5 SAFETY INSTRUCTIONS SAFETY LABELS AND DECALS...

Page 7: ...6 NAMES OF COMPONENTS Lifting handle Fuel tank cap Control panel Startup handle Left enclosure Spark plug cover plate Muf er Remove right cover bolt Right enclosure Remove left cover bolt Knob...

Page 8: ...nal The ground terminal is used to externally ground the inverter arallel Connectors To increase AC power output the connector sockets are used to connect the two same type generator with special para...

Page 9: ...llow light means the amount of oil is too low POWER OUTPUT Output power percentage display GASOLINE FUEL METER Gasoline fuel level display VOLTAGE Voltage display FREQUENCY Frequency display TIME Repr...

Page 10: ...e can seriously damage internal parts of the generator Remove fuel tank cap and add gasoline to red horizontal indicating line oil level Fuel tank capacity 3 6L Oil 2 No oil is lled into this generato...

Page 11: ...repair carefully Tip The condition of the generator shall be inspected before using every time Pre operation inspection Fuel Check fuel level in fuel tank of the generator and fuel it if necessary Oil...

Page 12: ...up it is unnecessary to close the choke valve but turn the combination switch to RUN 4 First gently pull startup handle until guy cable is hooked tight and then pull it with effort Tip When pulling t...

Page 13: ...12 SHUTTING DOWN THE GENERATOR Turn the multi switch to OFF position 2 3 Unplug the power cord 1...

Page 14: ...e the power of generator by about 1 5 Every 300 m rising of ASL will reduce the power the generator by about 4 5 Generator wiring 2 When the generator is connected to household power source as a backu...

Page 15: ...t up Switch on electrical equipment Tip Before increasing engine speed energy saving switch must be switched to OFF If the generator set supplies power to multi loads or electrical equipment start fro...

Page 16: ...lacement capacity 225cc every 250 hours Check ll Replace Replace Check oil Inspection Clean Replace Clean Clean adjust Clean Check adjust Check adjust Clean Inspection Remove carbon deposit Every two...

Page 17: ...death Spark plug inspection 1 Spark plug is an important part of the generator which must be inspected regularly Remove decorative cover and spark plug cap of the generator 1 Insert the screwdriver i...

Page 18: ...retor is an important components of the engine The adjustment shall be carried out by a dealer with professional knowledge professional data and equipment to ensure that the adjustment is proper Repla...

Page 19: ...ir cleaner regularly If being used in a dusty environment it shall be maintained frequently Loosen the bolt on the right cover counterclockwise and remove the right cover 1 Remove screws to remove cov...

Page 20: ...fuel tank cap and fuel tank lter screen 2 Clean fuel tank lter screen with gasoline 3 Wipe lter screen dry and put it back into fuel tank 4 Reassemble fuel tank cap Be sure to screw fuel tank cap tig...

Page 21: ...ctrical equipment Running time of the engine depends on remaining fuel in the fuel tank Open the generator right exterior cover and enter the carburetor Locate the clear plastic hose from the carburet...

Page 22: ...e closed 8 Place the generator set in a clean and dry area 9 Generator transport 2 When the generator set is transported it shall be ensured that there is no fuel spilling Do not ll excessive fuel int...

Page 23: ...22 TROUBLESHOOTING...

Page 24: ...23 TROUBLESHOOTING...

Page 25: ...soline Noise dB at 7m 25 load Rated Power kW Max Power kW Rated Voltage V Rated Frequency Hz Rated Power Factor Phase Number Run Time 25 h Overall Dimension mm Net Weight kg YS4000i Stroke x Bore mm 1...

Page 26: ...25 CIRCUIT DIAGRAM YS4000i SCHEMATICS...

Page 27: ...26...

Page 28: ...as better as possible in product design development production inspection etc to make our production can keep orderly And will continue to make improvement to make sure that keep the competitiveness...

Reviews: