Press and hold down the “
” button
for more than 2 seconds to enter the outdoor temperature alert setting,
the first is the upper limit alert setting of the outdoor temperature. Use the “
▲
” and “▼”
buttons to set the upper
limit alert value
Press “
” to confirm your setting
,
switch to the lower limit alert value of outdoor temperature. Use the
“
▲
” and
“▼”
buttons to set the upper limit alert value
Press “
” to confirm your setting and to end the setting procedure.
When setting the upper and lower limit alerts for outdoor temperature, press the “
” button to switch the alert
settings for setting the upper and lower outdoor temperature limits of different channels.
During the time setting process, double-click th
e “
” touch area to exit the setting mode directly.
F.Y.I.:
After 20 seconds without pressing any button, the clock switches automatically from Set Mode to Normal Time
Mode.
Temperature alert
Press the
“
”
button to turn on or off the temperature alert function. After the temperature alert is turned on,
the alarm icon “
” will be displayed in the ALERTS box, indicating that the temperature alarm has been
turned on
The outdoor temperature alert is independent for each channel, you need to set the corresponding channel,
you need to press the "
" button to convert to the channel number to be displayed, and then press the "
"
button to turn on or off the temperature alert
When the temperature exceeds the set temperature range, an alarm will be activated and the weather station
will emit three beeps continuously. At the same time, the temperature alarm in the alarm icon
“
”
flashes, and
its temperature value and the alarm upper limit icon
“
”
or the lower limit icon
“
”
also flash. In addition,
every time the temperature alarm is triggered after the temperature is updated, the weather station will issue a
BI sound prompt
In this alert mode, press any button to stop the alarm sound, and the warning is still displayed.
Temperature frost
warning
When the temperature of outdoor sensor is
–
1°C (+30°F) to + 3°C (+ 37°F), the frost alarm will be activated, the
frost alert icon “
” flashing.
Comfort and mildew risk instructions
Indoor comfort level is calculated according to the indoor temperature and humidity, a total of 5 levels.