background image

°C/°F temperature display: 

 The temperature is displayed either in °C/°F. Briefly pressing the “

” button allows 

you to switch between the individual modes. 

 

Comfort display: 

 Indoor comfort level is calculated according to the indoor temperature and humidity, 

a total of 5 levels. 
 

 

 

 

 

 

Comfortable            

                    too cold or too hot 

 

Displaying temperature/humidity/

 

barometric pressure and 

temperature/humidity trend: 

 

The current indoor temperature/humidity/barometric pressure and the 

temperature/humidity trend (indoors) are shown in the LCD display. 

 

After successfully connecting with the remote sensor, the weather station can 

display the remote temperature/humidity and the temperature/humidity trend 
(remote)     

 

You may see the following displays: 

    The temperature/humidity is rising. 

    The temperature/humidity is remaining constant. 

    The temperature/humidity is falling. 

 

Remote sensor transmission: 

 When the Weather Station successfully receives signals from the wireless sensor, the 

temperature and humidity of the "REMOTE SENSOR" are displayed on the "REMOTE 
SENSOR" column of the weather station.   

 The weather station can connect up to 3 channel wireless sensor registration, the 

use of multiple wireless sensor, the wireless sensor channel cannot choose the same 
channel at the same time (a total of 1, 2, 3 channel can choose,) 

 Press the “

” key can switch the display of different channels of remote 

temperature and humidity, when displaying the symbol "

 

  ", will display the 

channel every 5 seconds automatically switch a channel 

Summary of Contents for YC9444

Page 1: ...Youshiko YC9444 Radio Control Weather Sta on...

Page 2: ...ith a USB charging socket to charge Mobile phones etc Please keep the charging devices near the weather station only when charging otherwise avoid keeping those devices near the weather station as int...

Page 3: ...RCC If the reception of RCC signal fails due to signal interference or weak signal it will start again at 4 00am If fails again it will start again at 5 00am After 5 00am whether successful or not it...

Page 4: ...deactivate the automatic channel switching by pressing the loop mark will disappear in the channel zone on the screen Please note that the transmitting distance is within about 60m 196feet The displa...

Page 5: ...ture Indoor temperature measurement ranges 0 C 32 F 50 C 122 F Remote temperature measurement ranges 20 C 4 F 60 C 140 F Temperature alternatively in C or F Remote thermometer and frost alert Minimum...

Page 6: ...A6 Barometric pressure A7 Histogram shows the trend of 24 hours of atmospheric pressure A8 Indoor Humidity A9 Indoor comfort A10 Indoor Temperature A11 Weather Forecas ng Part B Back bu on and power B...

Page 7: ...Part C Wireless Remote Sensor C1 LCD display Temperature C2 LCD display Humidity C3 Transmit signal LED C4 C F bu on C5 TX bu on C6 CHANNEL 1 or 2 or 3 switch C7 Ba ery compartment...

Page 8: ...7 minutes of any restart or changing of new fresh batteries The radio mast icon starts to ash During the process the display screen will automatically turn o to reduce other interference After the pr...

Page 9: ...rect hour Press to con rm your setting the Minute displays starts to ash Now use and buttons to set the correct minute Press button to con rm your setting the Month and Date icon display starts to ash...

Page 10: ...larm will sound for 2 minutes if you do not deac vate it by pressing any bu on In this case the alarm will be repeated automa cally a er 24 hours Rising alarm sound crescendo dura on 2 minutes changes...

Page 11: ...d the temperature humidity trend remote You may see the following displays The temperature humidity is rising The temperature humidity is remaining constant The temperature humidity is falling Remote...

Page 12: ...show the maximum temperature and humidity values Twice to sow the minimum temperature and humidity values Three times to return to the current temperature and humidity levels To reset the maximum and...

Page 13: ...pper limit of the alarm temperature setting the activation of the upper limit alarm symbol ashing When the temperature is lower than the lower limit of the alarm temperature the lower limit alarm is a...

Page 14: ...the following displays The barometric pressure will rise The barometric pressure will remain constant The barometric pressure will fall Also please note Outdoor sensor collect real time data and weath...

Page 15: ...personal preferences of di erent brightness backlight or turn o the backlight Turn o backlight when you can touch the eld to light the backlight 15 seconds Battery replacement Use alkaline batteries o...

Page 16: ...ereby declares that the product fully complied to applicable guidelines and corresponding standards and requirements of UKCA and other relevant provisions of Directive 1999 5 EC LIABILITY DISCLAIMER E...

Page 17: ...of this product may change without prior no ce This product is not a toy keep out of the reach of children No part of this manual may be reproduced without wri en authoriza on of the manufacturer Sup...

Reviews: