1)
Turn ON the AC circuit breaker on each Microinverter AC branch circuit.
2)
Turn ON the main utility-grid AC circuit breaker. Your system will start producing power after a locally
mandated delay, usually 5 minutes..
3)
The units should start blinking green every 2 seconds five minutes after turning on the AC circuit break
-
er. This means they are producing power normally, but have not yet connected to the ECU. After the ECU
has been plugged in, setup acknowledges the Microinverters, they will start to blink green every 10 sec-
onds.
4)
Install and setup the ECU according to the instructions in the ECU manual
5)
The Yotta DPI-208 and DPI-480 Microinverters will start to send performance data over ZigBee to the
ECU. The time required for all the Microinverters in the system to report to the ECU will vary with the
number of Microinverters in the system. You can verify proper operation of the Yotta DPI-208 and DPI-480
Microinverters via the ECU. See the ECU Installation and Operation Manual for more information.
To operate the DPI-208 and DPI-480 microinverter PV system:
5. DPI-208 and DPI-480 System Operating Instructions
14