background image

EPDT-213b

 

 

3. Operation 

 

 

OB-30, OB-30U 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Heating  the  thermal  bulb  [20]  makes  its  inner  pressure  rise,  while  cooling  it  makes  the  pressure  lower. The 
bellows [14] expands/contracts responding to the change in the internal pressure that is transmitted through 
the capillary tube [21], and this allows the valve [4] open/close. 
When the temperature of the thermal bulb rises, the bellows expands and applies lifting force to the spindle [7] to 
close the valve. When the temperature of the bulb lowers, the downward force applied to the spindle by the spring 
[11] opens the valve.

 

The set temperature can be adjusted by turning the handle [12] to change the load of the spring. 

  No. 

Part name 

1  Body 

2  Spring chamber 

  3  Disc 

4  Valve 

5  Valve seat 

  6  Balance bellows 

7  Spindle 

8  Nut 

9  Guide 

10  Guide 

11  Spring 

12  Handle 

13  Bellows follower 

14  Bellows 

15  Ring 

16  Gasket 

17  Bolt 

18  Bushing 

19  Washer of packing 

20  Thermal bulb 

21  Capillary tube 

*22  Packing 

The  parts  marked  “*”  are 
available  as  consumable 
supply. 
 
Thermal  bulb  with  Thermal 
well (stainless steel) does not 
need  bushing  for  thermal 
bulb. 

OB-30 

OB-30U 

Summary of Contents for OB-30

Page 1: ...d result in death or serious injury Caution This symbol indicates a hazardous situation that if not avoided may result in minor or moderate injury or may result in only property damage Table of Conten...

Page 2: ...Pa Material Thermal bulb Copper pipe Nickel chrome plated Capillary tube Copper Flexible tube Stainless steel Standard capillary length 2 m Connection JIS R1 2 screwed Available with thermal well stai...

Page 3: ...Nominal Size d L Weight kg Capillary length Weight 15A Rc 1 2 75 2 1 2 m 0 6 kg 20A Rc 3 4 80 2 2 25A Rc 1 90 2 4 OB 30U OB 31U OB 30U OB 31U Body mm Sensor Nominal Size d L Weight kg Capillary lengt...

Page 4: ...lve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 opens the valve The set temperature can be adjusted by turning the handle 12 to change the load o...

Page 5: ...orce to the spindle 7 to open the valve When the temperature of the bulb lowers the downward force applied to the spindle by the spring 11 closes the valve The set temperature can be adjusted by turni...

Page 6: ...P2 and steam flow rate are 0 2 MPa 0 15 MPa and 20 kg h respectively first find intersection point a of the inlet pressure of 0 2 MPa and the outlet pressure of 0 15 MPa Trace down vertically from th...

Page 7: ...re and flow rate are 0 3 MPa 0 15 MPa and 1 m3 h respectively first find intersection point a of the differential pressure P of 0 15 MPa 0 3 MPa 0 15 MPa before and after the valve and the flow rate o...

Page 8: ...Failure to follow this notice hampers correct temperature regulation 11 Do not apply excessive load torque or vibration to the product Failure to follow this notice may result in malfunction or a dra...

Page 9: ...lve Capillary tube 5 4 Assembly of body and sensor Place the bellows follower 13 which is packaged with the body into the bellows 14 with its flat surface facing downward and then screw it into the lo...

Page 10: ...r hammer and can heavily damage the main parts of the product Be sure to follow the procedure below 1 Close the stop valves at the inlet and outlet sides of the product Open the bypass stop valve and...

Page 11: ...t us to retighten the gasket or disassemble the product to replace the part 2 Balance bellows 6 is damaged 2 Please contact us to disassemble the product and replace the part OB 31 OB 31U Trouble Caus...

Page 12: ...hock to the thermal bulb Warning Inspection must be done by experienced professional or valve manufacturer Completely discharge the pressure inside of the product piping and equipment prior to disasse...

Page 13: ...improvement without any prior notice After the discontinuation of the product Yoshitake supplies the repair parts for 5 years otherwise individually agreed 3 This warranty does not cover the damage d...