10 |
P a g e
ELECTRICAL WORKS INSTRUCTIONS
_________________________________________
This fireplace must be grounded
1.
A standard electrical outlet must be close to the fireplace. If the electric outlet is required
to be concealed, it can be located above or on the right hand side of the fire and behind
the glass face.
2.
DO NOT INSTALL THE FIREPLACE WHERE THE HEATER IS DIRECTLY
ABOVE AN OUTLET.
The heater is located in the center of the fireplace base.
3.
If the power supply cable becomes damaged in any manner it
MUST
be replaced.
4.
Always ensure that all electrical work complies with the relevant Building Codes. All
electrical work should be carried out by a qualified electrician.
5.
Please observe these instructions as failure to do so may result in electric shock or other
injury.
GROUNDING INSTRUCTIONS
___________________________________________________
This fireplace is for use on 120 volts. The cord has a plug as shown in (A) at
Figure 5
. An
adapter as shown in (C) is available for
connecting three-blade grounding type
plugs to two-slot receptacles. The
green grounding lug extending from
the adapter must be connected to a
permanent ground such as a properly
grounded outlet box. The adapter
should not be used if a three-slot
grounded receptacle is available.
Fig. 5