3. Volume Control 

The Volume control enables the YSM-2 Series monitors to be properly matched 

to various systems enabling the best calibration between the devices. 

The Level can be adjusted in two ways, 

i.  as a Volume Control. Connect a line in from the line-level 

source into the YSM-2 Series monitor’s input located at the 

back of the unit, proceed to rotate the Level control located at 

the rear of the monitor counter clockwise for minimum gain/off 

and full clockwise for maximum gain (sensitivity). Please note, 

always start with the Level control at minimum (off) and slowly 

bring up to desired level.

ii.  if you are using a mixing console to feed the input of the YSM-2 

powered monitor, set the dB gain control to the desired level and 

then proceed to the Level control on the YSM-2 powered monitor 

and slowly bring up to the desired level.

4. Low Frequency Adjust

The default setting for the Low Frequency Ad-

just is 0, which should be used when the unit is 

against a single wall (Half Space). If the monitors 

are placed in the middle of a room (Full Space) 

and more low-end response is needed, set the 

select switch to +2. As another example, if your 

monitors are placed in the corner of the room (¼ 

Space), it is recommended that you set the LF 

setting to -2.

5. High Frequency Adjust

The default setting for the HF (high frequency) 

is 0 which is a flat response in normal near field 

conditions. If the room is over dampened it might 

be desirable to increase the HF trim to +2, this 

will increase the high frequency response, the 

opposite would hold true for an under dampened room with a lot of reflec

-

tions that can become quite challenging for the ears, try the setting at -2.

6. Limiters

The YSM-2 Series has built in HF and LF limiters. The limiters will pro

-

tect against over excursion, will prevent amp clipping, and will prevent 

any voice coils from overheating. They will only activate when necessary, 

and are transparent to the user. This ensures accurate reproduction of 

music, but also protects the components from any damage.

Full Space Placement

(full area)

1/2 Space Placement

(against the wall)

1/4 Space Placement

(in corner)

High

Freq

2

0 dB

2

2

0

2

Low

Freq

Summary of Contents for TWO Series

Page 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR YSM5 S E R I E S T W O YSM6 S E R I E S T W O YSM8 S E R I E S T W O POWERED STUDIO MONITORS YSM S E R I E S T W O YSM5 2 YSM6 2 YSM8 2 ...

Page 2: ...sse dispose de deux lames en plus d une troisième tige qui connecte à la masse La lame plus large ou la tige de mise à la masse est prévu pour votre sécurité La prise murale est désuète si elle n est pas conçue pour accepter ce type de prise avec dispositif de sécurité Dans ce cas contactez un électricien pour faire remplacer la prise murale Évitez d endommager le cordon d alimentation Protégez le...

Page 3: ...mic range at all levels Transparent signal processing and bi amplification has been optimized for each driver The woofer and Tweeter have been perfectly time aligned to eliminate any phase irregularities usually associated with 2 way designs 1 Mains Voltage Cord and Fuse Replacement The YSM 2 Series universal supply will accept any voltage between 100VAC and 240VAC 50 60Hz NOTE If the fuse needs r...

Page 4: ...ngle wall Half Space If the monitors are placed in the middle of a room Full Space and more low end response is needed set the select switch to 2 As another example if your monitors are placed in the corner of the room Space it is recommended that you set the LF setting to 2 5 High Frequency Adjust The default setting for the HF high frequency is 0 which is a flat response in normal near field con...

Page 5: ... été conçus pour assu rer l excellence sonore offrant une large gamme dynamique à tous les niveaux Le traitement transparent du signal et la bi amplification ont été optimisés pour chaque haut parleur L alignement temporel exacte du woofer et du tweeter permet d éliminer les irrégularités de phase gé néralement associées aux modèles à deux voies 1 RemplacementdelaTensionduSecteur duCordonetduFusib...

Page 6: ...ixage pour alimenter l entrée du moniteur amplifié YSM 2 réglez la commande de gain dB sur le niveau souhaité puis passez à la commande de niveau du moniteur amplifié YSM 2 et amenez la lentement au niveau souhaité 4 Réglage des Basses Fréquences Le réglage par défaut de l ajustement des basses fréquences est 0 ce qui doit être utilisé lorsque l unité est contre un seul mur Half Space Si les monit...

Page 7: ...êtage de l amplificateur et la surchauffe des bobines mobiles Ils ne s activent que lorsque cela est nécessaire et sont trans parents pour l utilisateur Cela garantit une reproduction précise de la musique tout en protégeant les composants de tout dommage Full Space Placement full area 1 2 Space Placement against the wall 1 4 Space Placement in corner ...

Page 8: ...Class D Class D Class D LF Distor on 0 01 0 01 0 01 LF Processing Integrated DSP Integrated DSP Integrated DSP Cooling Scheme convec on convec on convec on Power Cable included included included Power Switch Back with LED on Baffle Back with LED on Baffle Back with LED on Baffle Power Consump on typ max 60W 60W 60W Inputs 1 4 inch Jacks 1 1 1 Inputs XLR 1 1 1 Inputs RCA 1 1 1 Input Sensi vity Vrms...

Page 9: ...on BF 0 01 0 01 0 01 Traitement BF DSP intégré DSP intégré DSP intégré Système de refroidissement convec on convec on convec on Câble d alimenta on inclus inclus inclus Commutateur d alimenta on Arrière avec DEL sur baffle Arrière avec DEL sur baffle Arrière avec DEL sur baffle Consomma on électrique typ max 60W 60W 60W Entrées Jacks 1 4 pouce 1 1 1 Entrées XLR 1 1 1 Entrées RCA 1 1 1 Sensibilité ...

Page 10: ...D i a g r a m f o r Y S M 5 2 Y S M 6 2 Y S M 8 2 D E S I G N E D M A N U FA C T U R E D B Y Y O R K V I L L E S O U N D RCA Unbalanced 5 6 8 Inch Woofer 1 Inch Dome Tweeter TRS Balanced XLR Balanced DSP Low Freq High Freq ADC DAC HF LF LEVEL ...

Page 11: ...re nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de la série de moniteurs de ...

Page 12: ... Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners YSM 2 SERIES 00 1v0 October 13 2021 ...

Reviews: