background image

 1

Synergy SA221S Powered Speaker

Thank you for choosing Yorkville’s Synergy SA221S subwoofer, the companion subwoofer to the SA153. The SA 

series excels in sound reinforcement applications where a line array is desired but cannot be easily accommodated. 

Cabinet Features

The SA221S is constructed of high strength multiply birch plywood for ultimate durability. There are 2 woofers, 

each 21-inch long-throw.

Electronic Features

A Yorkville proprietary DSP platform provides processing to prevent over-excursion (X-Max), voice coil over-

heating (VC thermal) and clipping. The DSP uses IIR filters for crossover and equalization and there is a small 

delay added to time align with the SA153 top box. The X-Max limiter and the VC thermal limiter are both fre-

quency sensitive and calibrated to match the characteristics of the driver and cabinet system. The VC thermal 

limiter can be advanced to limit the power draw in cases where there is less than ample power available. The 

X-Max limiter is faster, pretty much instantaneous. The VC thermal limiter is slower reacting, typically operating 

near the end of a bass beat at 120 bpm.

The amplifier is a high headroom Class-D design. There is a large capacitor bank so that bass transients are 

less dependent on the quality of the power line.

The limiter indicators indicate when the X-max or VC thermal limiters are active. Typically, the X-max 

limiter is more active but this is content dependent. The effect of the line power advance can be observed by 

carefully watching these limit lights as the control is changed while operating in limit. The VC thermal indica-

tor will come on sooner as the Average Power limiter is advanced. With many types of music, the effect of 

the VC-therm limiter will be minimal.

1. Power Switch and Indicator 

The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup-

plied. When the power is removed or the power switched is moved to the off position the green power indicator 

will blink while the power supply is discharging. The processing circuitry will not reboot unless the power supply 

is fully discharged before being turned back on. It is not necessary to reboot however. Turning the power back 

on before the power supply is discharged will simply resume normal operation.

2. PowerCON TRUE AC Loop Thru 

The SA221S is equipped with a powerCON TRUE inlet-outlet mains connector. The powerCON outlet at 

the rear of the SA221S can power another Synergy cabinet. A special power cable accessory called SACA-

BLELOOP is required for this AC loop thru connection. Call your local Yorkville dealer about this accessory.

IMPORTANT: DO NOT OVERLOAD THE AC MAINS SUPPLY BY CONNECTING TOO MANY CABINETS 

ON ONE CIRCUIT! PLEASE Read “LINE CURRENT LIMIT CONTROL” and “CASCADE INSTALLA-

TION” IN THIS MANUAL FOR TECHNICAL GUIDANCE. 

3. Input Jack 

This female XLR accepts line level XLR microphone cables. For best noise reduction use balanced sources.

4. Dual Link Outputs

These XLR male connectors can be used with a standard XLR cable to daisy-chain up to 20 SA221S cabinets 

without signal degradation. Simply loop from one cabinet’s Link jack to the next cabinets Input jack. In many 

cases this limit of 20 cabinets can be exceeded, consult Yorkville Sound for more details.

5. SA221S Level Control

This control adjusts the volume level of the SA221S relative to the input signal level. Mixers and other audio 

sources connected to the SA221S tend to have different output voltages, which mean the level control on the 

SA221S is used to fine tune the cabinet’s volume relative to the mixer settings. It is perfectly acceptable to set 

the SA221S Level above or below the center 0 dB setting.

Summary of Contents for Synergy SA221S

Page 1: ...OWNER S MANUAL MANUEL DE L UTILISATEUR SA221S ...

Page 2: ...urs qui produisent de la chaleur Les dispositifs marqués d une symbole d éclair sont des parties dangereuses au toucher et que les câblages extérieurs connectés à ces dispositifs de connection extérieure doivent être effectivés par un opérateur formé ou en utilisant des cordons déjà préparés Cordon d Alimentation Ne pas enlever le dispositif de sécurité sur la prise polarisée ou la prise avec tige...

Page 3: ...nimal 1 Power Switch and Indicator The green power LED illuminates when the power switch is turned to the On position and AC voltage is sup plied When the power is removed or the power switched is moved to the off position the green power indicator will blink while the power supply is discharging The processing circuitry will not reboot unless the power supply is fully discharged before being turn...

Page 4: ...erage power is excessive then the power will be limited This control works by advancing the limiter that limits the voice coil temperature and by monitor ing the current draw In the 16 amp position 8 amp CE the average power is limited only by the voice coil temperature In the 12 amp position 6 amp CE with most music the limiter will be only active occasionally depending on the music content In th...

Page 5: ... CURRENT LIMIT OUTPUT VC Therm Limit 8 12 24 4 6 6 2 2 1 Off Off 0 0 SUB LEVEL dB 20 AMP 12 12 AMPS 8 8 6 6 16 16 16A MAX Output 12A 90 Output 8A 80 Output 6A 60 Output HP OUTPUT TO SA315S ONLY HP OUTPUT 50Hz 50Hz Lowpass for use with SA315S CONNECTED IN PARALLEL INPUT Activity Power X MAX Input Clip 100Hz Lowpass LINE CURRENT LIMIT OUTPUT VC Therm Limit 8 12 24 4 6 6 2 2 1 Off Off 0 0 SUB LEVEL d...

Page 6: ...gement Limiter Excursion Thermal RMS Clipping LED Indicators Power Excursion Limit Thermal RMS Limit Input Clip Activity Enclosure Materials Multi ply 15mm Birch Plywood Casters 4 x Locking Swivel Casters On Rear Of Cabinet Stand Adapter 2 1 Top 1 Side UHMW Skid Glides 2 Rear Stacking Feature Rubber Feet and Cups Side and Bottom Covering Finish Paint Dimensions DWH inches 32 750 37 750 including c...

Page 7: ...que la commande est modifiée pendant le fonctionnement en limite Le voyant VC therm s allume plus tôt lorsque le limiteur de Puissance Moyenne est avancé Avec de nombreux types de musique l effet du limiteur VC therm sera négligeable 1 Interrupteur et Indicateur d Alimentation Le voyant d alimentation vert s allume lorsque l interrupteur d alimentation est réglé sur la position ON et que la tensio...

Page 8: ...ce d alimentation de 20 ampères La commande de limitation de la puissance moyenne permet de réduire la puissance pour permettre un fonctionnement avec une alimentation limitée Les transitoires à pleine puissance seront permises mais si la puissance moyenne est excessive la puissance sera limitée Cette commande fonctionne en faisant avancer le limiteur qui limite la température de la bobine mobile ...

Page 9: ... CURRENT LIMIT OUTPUT VC Therm Limit 8 12 24 4 6 6 2 2 1 Off Off 0 0 SUB LEVEL dB 20 AMP 12 12 AMPS 8 8 6 6 16 16 16A MAX Output 12A 90 Output 8A 80 Output 6A 60 Output HP OUTPUT TO SA315S ONLY HP OUTPUT 50Hz 50Hz Lowpass for use with SA315S CONNECTED IN PARALLEL INPUT Activity Power X MAX Input Clip 100Hz Lowpass LINE CURRENT LIMIT OUTPUT VC Therm Limit 8 12 24 4 6 6 2 2 1 Off Off 0 0 SUB LEVEL d...

Page 10: ...la consommation d énergie Limiteur Excursion thermique RMS écrêtage Indicateurs DEL Puissance Limite d excursion Limite thermique RMS Clip d entrée Activité Matériaux du boîtier Contreplaqué de bouleau de 15mm Roues 4 roulettes pivotantes verrouillables à l arrière de l armoire Adaptateur de support 2 1 haut 1 côté Glissières de protection UHMW 2 Arrière Caractéristiques d empilage Pieds et coupel...

Page 11: ... E D B Y Y O R K V I L L E S O U N D block diagram SYNERGY SA221S 00 1v1 Output Input XLR Sub Level 50Hz LP AC Line Sense AC Line Current Sense Line Current Limit Microcontroller DSP ADC DAC HP Output 2 3 1 2 3 1 2 3 1 1 3 2 AMP AMP Act VC Therm X Max Input Clip Limit Pwr ...

Page 12: ...10 ...

Page 13: ...ctrical cords that have worn or damaged insulation and remember to pull the plug not the cord to prevent damage to the cord Only replace with the equivalent heavy duty cord supplied by the manufacturer 4 The AC supply cord should be routed so that it is unlikely that it will be damaged Protect the power cord from being walked on or pinched If the AC supply cord is damaged DO NOT OPERATE THE UNIT T...

Page 14: ...gée et n oubliez pas de tirer sur la fiche et non sur le cordon pour éviter d endommager ce dernier Ne remplacez le cordon électrique que par un cordon équivalent à usage intensif fourni par le fabricant 4 Le cordon d alimentation CA doit être acheminé de manière qu il soit peu probable qu il soit endommagé Protégez le cordon d alimentation pour qu il ne soit pas piétiné ou pincé Si le cordon d al...

Page 15: ...re nom auprès de Yorkville Sound ou de votre détaillant Si pour une raison quelconque ce produit devient défectueux durant les deux années qui suivent la date d achat initial dix ans pour l ébénisterie retournez le simplement à votre détaillant Yorkville avec la preuve d achat original et il sera réparé gratuitement Ceci inclus tous les produits Yorkville à l exception de la série de moniteurs de ...

Page 16: ...e Niagara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8746 Manual Owners SYNERGY SA221S 00 1v2 June 24 2022 ...

Reviews: