background image

 6

weight of cabinet only

PS12SF

4 Top

3/8-16

weight of cabinet only

PS15SF

4 Top

3/8-16

PS18SF

4 Side

weight of cabinet only

3/8-16

DOC-flyware-PS__S-00-1v1. • July 22/2020

EYEBOLT  INSTALLATION

Remove

Flat-Head Bolt

 and

replace with 

Forged Shoulder Eyebolt!

DO NOT

 Remove

Flat-Head Bolts

on the Side of Cabinet/s.

1. DESCRIPTION

Many of the popular models in the Yorkville speaker cabinet line are now equipped with flying 

hardware for overhead suspension applications. Depending on the model, two or more internal 

braces have been provided for rigging purposes. Each brace contains two bolt holes and provides 

center-of-gravity fly-points for use with in-line or angular loads. Many of the models will support 

additional suspended cabinets according to their specified working load limits.

IMPORTANT!!

THE RIGGING OF LOUDSPEAKER SYSTEMS IS AN EXTREMELY SERIOUS MATTER. OVERHEAD RIGGING REQUIRES EXTENSIVE 
EXPERIENCE, INCLUDING (BUT NOT LIMITED TO) CALCULATING WORKING LOAD LIMITS, HARDWARE INSTALLATION, AND 
PERIODIC SAFETY INSPECTION OF ALL HARDWARE AND CABINETRY. IF YOU LACK THESE QUALIFICATIONS, DO NOT ATTEMPT 
THE INSTALLATION YOURSELF, BUT INSTEAD USE A PROFESSIONAL STRUCTURAL RIGGER. IMPROPER INSTALLATION CAN 
RESULT IN BODILY INJURY OR DEATH. CONSULT A STRUCTURAL ENGINEER TO CALCULATE ADDED LOADS FOR A BUILDING. 
STRUCTURAL REINFORCEMENT MAY BE NECESSARY TO INSURE A SAFE INSTALLATION.

2. REQUIRED TOOLS

4.5mm (7/32”) Hex Wrench

Thread lock adhesive (Removable Type)

3. EYEBOLT INSTALLATION

a) Using a 4.5mm (7/32”) hex wrench, remove the flat head bolts from the top or bottom of the speaker enclosure 

to expose the tapped holes (on TX models, the flat head bolts are located within the track rails), as shown below. 

Be sure to keep these handy as they will be needed to seal the cabinet after the eyebolts are removed.

IMPORTANT!!

USE ONLY LOAD RATED FORGED EYEBOLTS. THESE MAY BE PURCHASED THROUGH YORKVILLE SOUND OR ATM FLY-WARE™. 
TO INSURE CABINET-BRACING STRENGTH, MAKE SURE ALL FLY-POINTS ARE SECURED WITH EITHER AN EYEBOLT OR FLAT 
HEAD HEX BOLT.

b) Place a drop of thread-lock adhesive on the threads of the eyebolt and insert one into exposed hole. Tighten each 

eyebolt by hand until its fits snugly against the cabinet. Further tighten each eyebolt by rotating it another half turn. Be 

sure to insert eyebolts in the threaded hole directly in-line with the suspension cable. Always follow the eyebolt 

manufacturers installation and use instructions.
c) Suspend each cabinet according to working load calculations and practices recommended by the rigging

hardware manufacturer.

IMPORTANT!!

ON MODELS WITH ONLY TWO TOP SUSPENSION POINTS THE SUPPLIED PULL BACK AT THE REAR OF THE BOTTOM 
CENTER PANEL OF THE CABINET IS NOT TO BE USED AS A SUSPENSION POINT. THIS POINT TO BE USED FOR PULL BACK 
PURPOSES ONLY.

IMPORTANT!! 

READ ALL ENCLOSED INSTRUCTIONS ABOUT PROPER USE OF HARDWARE. TO INSURE PROPER 

INSTALLATION, FOR TECHNICAL INFORMATION ON SUSPENSION TECHNIQUES AND EXTERIOR ACCESSORY INFORMATION 
WE SUGGEST CALLING ATM FLY-WARES TECHNICAL SERVICES IN THE UNITED STATES AT (310)639-8282 MONDAY THROUGH 
FRIDAY FROM 9 AM TO 6 PM (PST) OR FAX AT (310)639-8284. YORKVILLE SOUND MAKES NO CLAIMS AS TO THE SAFETY OF 
THE ENCLOSURES IF RECOMMENDED LOAD LIMITS AND HARDWARE ARE NOT STRICTLY ADHERED TO. NOR DOES IT MAKE 
ANY SAFETY CLAIMS TO THE RESULTANT INSTALLATION.

IMPORTANT!! 

TRACK RAILINGS: UNITS THAT INCORPORATE THE TRACK RAILING SYSTEM HAVE THE SAME WORKING LOAD 

LIMITS AS THEY DO WHEN THEY ARE USED WITH EYEBOLTS. THESE RATINGS MAY BE LIMITED AND BASED ON THE RATINGS 
OF THE TRACK FITTINGS THEMSELVES. PLEASE ENSURE THAT THE RATING OF THE CERTIFIED TRACK FITTINGS EXCEEDS 
NECESSARY WORKING LOAD LIMITS

.

4. WORKING LOAD LIMITS

Specified working load limits have been determined for the enclosure as follows:

Flyware - English

Summary of Contents for PARASOURSE Series

Page 1: ...PS12S PS15S PS18S PS12S REV2 PS15S REV2 PS18S REV2 Owner s Manual Manuel de L Utilisateur PS12S PS15S PS18S Cover...

Page 2: ...nt de la chaleur Les dispositifs marqu s d une symbole d clair sont des parties dangereuses au toucher et que les c blages ext rieurs connect s ces dispositifs de connection ext rieure doivent tre eff...

Page 3: ...Protection 2 5 Stand Mounting Adapter 2 PS12s PS15s et PS18s 3 1 Commutateur de Mode d Entr e 3 2 La Commande de Niveau Des PS12 PS15 et PS18 3 3 Prises d Entr e Link 4 4 Protection 4 5 Adaptateur de...

Page 4: ...r a powered mixer You can also use a speaker level signal from the parallel connection on an un powered speaker cabinet WARNING Do not plug in two speaker level sources to a single ES Series Powered S...

Page 5: ...en the limiter LED is Yellow the voice coil overheating protection is active this will compress the dynamics of the music At high levels the limiter will limit the gain of the PS Series Powered Subwoo...

Page 6: ...nal de niveau de haut parleur provenant de la connexion parall le sur une enceinte non amplifi e ATTENTION Ne branchez pas deux sources de niveau de haut parleur un seul caisson de basse amplifi de la...

Page 7: ...ion contre la surchauffe de la bobine mobile est active ce qui compresse la dynamique de la musique Durant une utilisation des niveaux lev s le limiteur devient actif et limite le gain du caisson de b...

Page 8: ...Actif ou Passif Actif Actif Actif Puissance Nominale watts 900 watts Nominale 1800 watts Pointe 1000 watts Nominale 2000 watts Pointe 1200 watts Nominale 2400 watts Pointe Max SPL dB 129dB Pointe 123d...

Page 9: ...e removed IMPORTANT USE ONLY LOAD RATED FORGED EYEBOLTS THESE MAY BE PURCHASED THROUGH YORKVILLE SOUND OR ATM FLY WARE TO INSURE CABINET BRACING STRENGTH MAKE SURE ALL FLY POINTS ARE SECURED WITH EITH...

Page 10: ...PROCURER DE YORKVILLE SOUND OU ATM FLYWARE POUR PR SERVER UNE FORCE MAXIMALE DE L ENTRETOISEMENT DU CABINET ASSUREZ VOUS QUE TOUS LES POINTS DE SUSPENSION SONT FIX S SOLIDEMENT AVEC SOIT UN BOULON IL...

Page 11: ...DIAG PS12S PS15S PS18S 00 1v1 BUFFERS WOOFER EQ LP EQ HP LP HP Excursion Red Clip Red Thermal Yellow CLASS D POWER AMP B l o c k D i a g r a m f o r P S 1 2 s P S 1 5 s P S 1 8 s D E S I G N E D M A N...

Page 12: ...9 Notes...

Page 13: ...pr s de Yorkville Sound ou de votre d taillant Si pour une raison quelconque ce produit devient d fectueux durant les deux ann es qui suivent la date d achat initial dix ans pour l b nisterie retourne...

Page 14: ...agara Falls New York 14305 USA Voice 716 297 2920 Fax 716 297 3689 WORLD HEADQUARTERS CANADA Yorkville Sound Limited 550 Granite Court Pickering Ontario L1W 3Y8 CANADA Voice 905 837 8481 Fax 905 837 8...

Reviews: