518676-BIM-C-0610
4
Johnson Controls Unitary Products
Nomenclature
Z S -10 N18 A T A AA 3 0 1 2 4 A
Product Category
Z = A/C, Single Pkg., R-410A
A = Std. Motor
Airflow
B = Std. Motor/Econo./Barometric Relief (Downflow
Only)
C = Std. Motor/Econo./Power Exhaust (Downflow Only)
D = Std. Motor/Motorized Damper (Downflow Only)
E = Std. Motor/Horizontal Economizer (No Baro.)
F = Std. Motor/Slab Econo./Power Exhaust
(Downflow Only)
G = Std. Motor/Slab Econo./Barometric Relief
(Downflow Only)
N = Hi Static
P = Hi Static/Econo./Barometric Relief
(Downflow Only)
Q = Hi Static/Econo./Power Exhaust
(Downflow Only)
R = Hi Static/Motorized Damper (Downflow Only)
S = Hi Static/Horizontal Economizer (No Baro.)
T = Hi Static/Slab Econo./Power Exhaust
(Downflow Only)
U = Hi Static/Slab Econo./Barometric Relief
(Downflow only)
Product Generation
1 = First Generation
C00 = Cooling Only. No heat installed
Heat Type and Nominal Heat Capacity
N12 = 120 MBH Input Aluminized Steel
N18 = 180 MBH Input Aluminized Steel
N24 = 240 MBH Input Aluminized Steel
S12 = 120 MBH Input Stainless Steel
S18 = 180 MBH Input Stainless Steel
S24 = 240 MBH Input Stainless Steel
E09 = 9 KW
E18 = 18 KW
E24 = 24 KW
E36 = 36 KW
E54 = 54 KW
Gas Heat Options
Electric Heat Options
-06 = 6.5 Ton
Nominal Cooling Capacity
-07 = 7.5 Ton
-08 = 8.5 Ton
-10 = 10.0 Ton
-12 = 12.5 Ton
Product Identifier
S = 11.2 + EER A/C
Voltage
T = 208/230-3-60
W = 460-3-60
X = 575-3-60
Product Style
A = Style A
B = Style B
A = No Options Installed
Installation Options
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
Additional Options
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
6.5-12.5 Ton Single Package Model Number Nomenclature
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
SS Drain Pan
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
CPC Controller, DFS, APS
Johnson Controller UNT 1126 (N2 protocol), DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/Simplicity®LINC
2" Pleated filters
BAS Ready Economizer (2-10 V.D.C. Actuator without a Controller)
Shipping Bag
Hot Gas Bypass (Standard on VAV, Optional on CV)
Variable Air Volume, VFD (not available with factory installed BAS options)
Variable Air Volume, VFD with Simplicity®LINC (not available with factory installed BAS options)
Variable Air Volume, VFD (BAS ready)
Variable Air Volume, VFD and Manual Bypass (BAS ready)
Variable Air Volume, VFD Ready (for customer-provided, field-installed drive)
Variable Air Volume, VFD Ready with Simplicity®LINC
(for customer-provided, field-installed drive)
Variable Air Volume, VFD and Manual Bypass with Simplicity®LINC
(not available with factory installed BAS options)
Variable Air Volume, VFD and Manual Bypass
(not available with factory installed BAS options)
Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned
4" Pleated filters