Technical Specification: Ducted Dc Inverter “YUHC” R-410A, 50Hz.

Model

Set

YUHC18DUBAAR-K

YUHC24DUBAAR-K

YUHC36DUBACR-K

YUHC48DUBACR-K

YUHC60DSBACR-K

Indoor

YUKC18DU-BAR-K

YUKC24DU-BAR-K

YUKC36DU-BCR-K

YUKC48DU-BCR-K

YUKC60DS-BCR-K

Outdoor

YUJC18DU-BAR

YUJC24DU-BAR

YUJC36DU-BCR

YUJC48DU-BCR

YUJC60DS-BCR

Power supply

V-Ph-Hz

220~240-1-50

220~240-1-50

380V~3~50Hz

380V~3~50Hz

380V~3~50Hz

Cooling

Capacity

Btu/h

 18,000 

 24,000 

 36,000 

 48,000 

 60,000 

Input

W

 1,570 

 2,130 

 3,260 

 4,250 

 4,840 

Rated current

A

 7 

 10 

 9 

 11 

 11 

Heating

Capacity

Btu/h

 21,000 

 28,000 

 40,000 

 53,000 

 62,000 

Input

W

 1,630 

 2,190 

 3,120 

 4,140 

 4,800 

Rated current

A

 7 

 10 

 8 

 11 

 11 

Max. input consumption

W

 2,600 

 2,800 

 3,560 

 4,750 

 5,950 

Max. current

A

 10 

 11 

 10 

 13 

 16 

Starting current

A

 1 

 1 

 1 

 1 

 1 

Compressor

Type

 DC Inverter Rotary 

 DC Inverter Scroll 

Input

W

 1,650 

 1,650 

 3,665 

 3,665 

 3,665 

Rated current (RLA)

A

 8 

 8 

 8 

 8 

 8 

Locked rotor 

Amp (LRA)

A

 28 

 28 

 28 

 28 

 28 

Protector

 Thermal 

Capacitor

µF

 50 

 50 

 50 

 50 

 50 

Refrigerant oil

ml

 480 

 480 

 500 

 500 

 500 

Indoor fan motor

Type

 AC Motor 

Input

W

 117 

 170 

 118 

 324 

 160 

Capacitor

µF

 3 

 7 

 3 

 10 

 10 

Speed (Hi/Me/Lo)

r/min

 900/800/690 

 1,100/1,020/900 

 820/695/620 

 870/770/700 

 870/770/700 

Indoor coil

Number of rows

 3 

 3 

 3 

 3 

 3 

Fin spacing

mm

 2 

 2 

 2 

 2 

 2 

Fin type

 Hydrophilic aluminium 

Tube outside dia.

mm

 Ø9.52 

Material Type

 Innergroove tube 

Coil length x 

height x width

mm

800×254×66

 800×254×66

 1,150×254×66 

 1,150×254×66 

 1,150×305×66 

Indoor air flow (Hi/Me/Lo)

m

3

/h

 1,020/870/700 

 1,275/1,170/1,030   2,070/1,950/1,860   2,400/2,300/2,200   2,800/2,700/2,600 

Indoor external static pressure (Hi)

Pa

 40 

 40 

 70 

 70 

 96 

Indoor noise level (Hi/Me/Lo)

dB(A)

 50/-/- 

 53/-/- 

 49/47/44 

 51/47/44 

 52/48/46 

Indoor unit

Dimension 

(WxHxD)

mm

 1,095×805×290 

1,095×805×290

 1,350×298×800 

 1,350×320×800 

 1,350×320×800 

Packing

(WxHxD)

mm

1,205×940×370

1,205×940×370

1,555×940×370

 1,555×440×940 

 1,555×440×940 

Net/Gross weight

kg

 38/45 

 38/45 

 48/57 

 70/80 

 70/80 

Outdoor fan 

motor

Input

W

 129 

 150 

 307 

 150×2 

 150×2 

Capacitor

µF

 3 

 3 

 10 

 3.5×2 

 3.5×2 

Speed

r/min

 770 

 800 

 740 

 800 

 800 

Outdoor coil

Number of rows

 2 

 2 

 1 

 1 

 1 

Fin spacing

mm

 2 

 2 

 2 

 2 

 2 

Fin type

 Hydrophilic aluminium 

Tube outside dia.

mm

 Ø9.52 

Tube Material

 Innergroove tube 

Coil length x 

height x width

mm

 630×660×44 

620×813×44

 955×915×22 

 715×610×22 

 1150×305×66 

Outdoor air flow

m

3

/h

 2,400 

 3,000 

 5,000 

 6,000 

 6,000 

Outdoor noise level

dB(A)

 56 

 55 

 57 

 58 

 58 

Outdoor unit

Dimension 

(WxHxD)

mm

840×677×310

894×860×302

990×960×340

940×1,245×340

940×1245×340

Packing

(WxHxD)

mm

965×770×395

1,043×915×395

1,120×1015×435

1,058×1300×435

1,058×1,300×435

Net/Gross weight

kg

 62.5/66.5 

 72/76.5 

 106/111 

 117/126 

 112/127 

Refrigerant R-410A

g

 1,650 

 2,200 

 2,600 

 3,550 

 4,200 

Throttle type

 EXV&Capillary 

Refrigerant piping Liquid side/

Gas side

mm

 6.35/12.7 

 9.53/16 

 9.53/16 

 9.53/16 

 9.53/16 

J368-EN.indd   6

2/1/07   9:40:56 AM

Summary of Contents for YUKC 07-18

Page 1: ...Installation Owner s Manual MODELS YUHC 18 60 YUKC 07 18 MINISPLIT AIR BLOWER EN 035M00065 000 J368 EN indd 1 2 1 07 9 40 52 AM...

Page 2: ...tomers with consistent reli ability in product service and support through superior quality service culture and distinctive technology Standard Refrigerant R 410A Model 18 24 30 60 Set YUHCxxFUAAAR YU...

Page 3: ...le or spill water or liquids on unit DANGER To prevent electric shock turn off the power or disconnect the power supply plug before beginning any cleaning or other routine maintenance Follow the direc...

Page 4: ...anual are for explanation purpose only They may be sightly different from the air conditioner you purchased The actual shape shall prevail OUTDOOR UNIT INDOOR UNIT DISPLAY PANEL I Infrared signal rece...

Page 5: ...Ph 1 1 1 1 1 1 Fan Air ow m3 h 1 160 1 460 2 070 2 070 2 400 2 800 Input Power W 117 170 118 118 118 227 Running Current A 0 53 0 77 0 54 0 54 0 54 1 03 Dimension Height mm 300 300 300 300 300 320 Wi...

Page 6: ...52 Material Type Innergroove tube Coil length x height x width mm 800 254 66 800 254 66 1 150 254 66 1 150 254 66 1 150 305 66 Indoor air ow Hi Me Lo m3 h 1 020 870 700 1 275 1 170 1 030 2 070 1 950 1...

Page 7: ...5 650 560 930 830 660 Indoor coil Number of rows 2 2 2 2 Fin spacing mm 1 5 1 5 1 5 1 7 Fin type Hydrophilic aluminium Tube outside dia mm 7 7 7 9 53 Tube Material Innergroove tube Coil length x heigh...

Page 8: ...27 000 30 000 W 2 638 4 103 6 155 2 900 4 100 7 000 7 900 8 792 Input W 1 300 1 600 2 038 1 300 1 600 2 100 2 750 2 739 Rated current A 6 3 7 8 11 0 6 3 7 8 11 0 13 2 13 2 Max input W 3 200 3 200 Max...

Page 9: ...NS 845 990 624 181 4 336 4 400 1 245 360 940 650 695 960 360 235 860 330 125 335 351 2 135 560 1 141 5 313 300 895 590 163 301 5 YUJC 18 YUJC 24 YUJC 30 36 YUJC 48 60 RRJC 18 27 310 300 520 688 790 J3...

Page 10: ...Installation place The indoor unit must be installed such that there is no short circuit of the cool discharge Comply to the installation clearance recommended Do not put the indoor unit where there i...

Page 11: ...t of refrigerant pipe Connecting point of drain pipe Gas side F Ceiling hole 470 450 Panel 500 Dust proof net Additional purchase Canvas air passage Additional purchase Panel Additional purchase 298 1...

Page 12: ...205 300 I I Back panel layout A 250 320 127 N 250x393 8 Main body 800 300 720 630 Connecting point of cold medium pipe Air side F Connecting point of drain pipe Ceiling hole 470 450 Panel 500 Dust pr...

Page 13: ...ibed in the installation chart does not mean that the same is applicable to the situation of an airtight Leave open two of three directions A B C CAUTIONS Chart 1 NECESSARY ROOM FOR INSTALLATION AND M...

Page 14: ...s or other objects Do not lean it more than 45 and do not lay it sidelong Please fasten the feet of this unit with bolts rmly to prevent it from collapsing in case of earthquake or strong wind Make co...

Page 15: ...lude a large number of oil traps it may be necessary to adjust to compressor charge NOTES Unit size 18 24 30 36 48 60 m 30 30 30 30 30 30 REFRIGERANT PIPING CONNECTIONS Refrigerant charge to be added...

Page 16: ...4 0 0 1 5 0 0 1 0 5 0 4 0 3 0 6 0 P a 9 0 8 0 7 0 m 3 1 5 0 0 1 6 0 0 1 7 0 0 1 8 0 0 2 0 1 9 0 0 2 0 0 0 1 0 5 0 4 0 3 0 6 0 P a 9 0 8 0 7 0 m 3 1 8 0 0 1 9 0 0 2 0 0 0 2 1 0 0 2 0 2 2 0 0 2 3 0 0 1...

Page 17: ...ctions do apply for products like washing machines air conditioner or electrical ovens 4 For power details of the air conditioner refer to the rating plate of the product 5 For any question contact yo...

Page 18: ...18 ENGLISH YUKC 07 YUKC 09 YUKC 12 YUKC 18 RRJC 18 RRJC 27 A F IPM PFC J368 EN indd 18 2 1 07 9 41 26 AM...

Page 19: ...INDOOR UNIT L N Power supply Power supply For 18 000 24 000 Btu h 1 Phase 1 Phase 380 415V 5 core cable 5x2 5mm 2 3 core sheild cable OUTDOOR UNIT Power supply 3 Phase 220 240V 3 core cable 3x2 5mm 2...

Page 20: ...ing Defrosting Mode under condition a SERVICE AND MAINTENANCE The units are designed to operate for long periods of time with a minimum of maintenance However the following operations must be performe...

Page 21: ...unit This is a normal condition when the air conditioner has not been used for a long time or during rst use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor...

Page 22: ...you started the sys tem 1 Remove charge repair evacu ate and recharge 2 Insulate them separately 3 Wait while unit has enough time to cool the room D The compressor runs con tinuously 1 Thermostat ad...

Page 23: ...move all refrigerant from each system of the unit into a suitable container using a refrigerant reclaim or recovery unit This refrigerant may then be reused if appropriate or returned to the manufactu...

Reviews: