24000Btu/h (1 PHASE)
Air Conditioner Link-circuit
(For R-410A, Cooling & Heating)
24000-36000Btu/h (1 PHASE)
Air Conditioner Link-circuit
(For R-407C, Cooling & Heating)

Chart 21

3-core cable 3x2.5mm

2

1-core sheild wire 1x0.5mm

2

3-core cable 3x2.5mm

2

OUTDOOR UNIT

INDOOR UNIT

POWER:
220-240V~50Hz

3-core cable 3x2.0mm

2

12000 Btu/h (1 PHASE)
Air Conditioner Link-circuit
(For R-410A, Cooling & Heating)
18000 Btu/h (1 PHASE)
Air Conditioner Link-circuit
(For R-410A, R-407C and R-22,
Cooling & Heating)

Chart 20

3-core cable 3x2.5mm

2

1-core sheild wire 1x0.5mm

2

5-core cable 5x2.0mm

2

OUTDOOR UNIT

INDOOR UNIT

POWER:
220-240V~50Hz

Chart 18

❥✱

The Speci

fi

 cation of Power

Power supply

Switch/Fuse
(Available locally)

Power wiring (indoor)

Power linking wiring (Outdoor)

Ground wiring

Strong elec-signal link wiring

Weak elec-signal link wiring

Ground wiring

Indoor
Unit

Outdoor
Unit

•  Ground the air conditioner properly in case to affect its anti-interference function

Chart 19

1.5m~2m

Insulating

material

Downward

declivity lower

than 1/100

Bend

S shape

Put as deep as possible
(about 10cm)

Downward declivity
lower than 1/100

VP30

WIRING

❥✱

Attaching wiring

1. The air conditioner should use separate power supply with rated voltage
2. The external power supply to the air conditioner should have ground wiring,

which is linked to the ground wiring of the indoor and outdoor unit.

3. The wiring work should be done by quali

fi

 ed persons according to circuit

drawing.

4. A leakage protector should be installed according to the National Standard

concerning electrical appliance.

5. Be sure to locate the power wiring and the signal wring well to avoid cross-

disturbance and their contact with connecting pipe or stop valve body.

6. The wiring attached to this air conditioner is 10m long. Be sure to prolong it

with wiring of the same type and proper length if necessary. Generally, do not
twist two wiring together unless the joint is soldered well and covered with
insulator tape.

7. Do not turn on the power until you have checked carefully after wiring.

TYPE

12000~18000 Btu/h

(Cooling&Heating)

24000-36000 Btu/h

(Cooling&Heating)

36000-60000 Btu/h

(Cooling&Heating)

POWER

PHASE

1-PHASE

1-PHASE

3-PHASE

FREQUENCY AND VOLT

220-240V~, 50Hz

220-240V~, 50Hz

380V 3N~, 50Hz

CIRCUIT BREAKER/FUSE (A)

20/16

40/25

40/20

INDOOR UNIT POWER WIRING (mm

2

)

3x2.5

5x2.5

INDOOR/OUTDOOR
CONNECTING
WIRING

(mm

2

)

GROUND WIRING

2.0

2.5

2.5

OUTDOOR UNIT
POWER WIRING

3x2.5

3x2.5

5x2.5

STRONG ELECTRIC
SIGNAL

5x2.0

(3x2.0)

3x2.0

(2x2.0)

3x2.0

(2x2.0)

WEAK ELECTRIC
SIGNAL

1-core sheild wire

1x0.5mm

2

2-core sheild wire

2x0.5mm

2

TYPE

12000~18000 Btu/h

(Cooling Only)

24000-36000 Btu/h

(Cooling Only)

36000-60000 Btu/h

(Cooling Only)

POWER

PHASE

1-PHASE

1-PHASE

3-PHASE

FREQUENCY AND VOLT

220-240V~, 50Hz

220-240V~, 50Hz

380V 3N~, 50Hz

CIRCUIT BREAKER/FUSE (A)

40/25

40/20

40/25

INDOOR UNIT POWER WIRING (mm

2

)

3x2.5

3x2.5

5x2.5

INDOOR/OUTDOOR
CONNECTING
WIRING

(mm

2

)

GROUND WIRING

2.0

2.0

2.0

OUTDOOR UNIT
POWER WIRING

3x2.0

5x2.0

STRONG ELECTRIC
SIGNAL

3x2.0

1x2.0

1x2.0

WEAK ELECTRIC
SIGNAL

❥✱

Wiring Chart

Installing wiring chart, refer to link circuit chart for details.

  CAUTION:

When wiring, please choose the corresponding chart, or it may

cause damage.

Timber over the beam

Roof beam

Ceiling

Hanging screw bolts

Chart 1

Chart 2

(Blade shape insertion)

(Slide insertion)

Steel bar

Embedding screw bolt

(Pipe hanging and embedding
screw bolt)

Chart 3

Hanging screw bolt

Supporting
angle steel

Hanging bolts

Chart 4

CONNECT THE DRAIN PIPE

1. Install indoor unit drain pipe

The outlet has PTI screw thread, Please use sealing materials and pipe sheath
(

fi

 tting) when connecting PVC pipes.

Cautions

2. Drainage test

•  Check whether the drainpipe is unhindered
•  New built house should have this test done before paving the ceiling.

3. Drain Elbow Installation

  Fit the seal into the drain elbow, then insert the drain elbow into the base pan

hole of outdoor unit, rotate 90

°

 to securely assemble them. Connect the drain

elbow with an extension
drain hose (Locally purchased),
in case of the condensate
draining off the outdoor unit
during the heating mode.
(Refer to Chart 17)

Wooden construction

New concrete bricks

For Original concrete bricks

Steel roof beam structre

Put the square timber traversely over
the roof beam, then install the hanging
screw bolts. (Refer to Chart 1)

Inlaying or embedding the screw bolts.
(Refer to Chart 2)

Use embedding screw bolt. (Refer to
Chart 3)

Install and use directly the supporting
angle steel. (Refer to chart 4)

Chart 17

The base pan hole
of outdoor unit

The base pan
hole of outdoor

Drain elbow

Seal

Seal

Drain elbow

•  The drain pipe of indoor unit must be heat insulated, or it will condense dew,

as well as the connections of the indoor unit.

•  Hard PVC binder must be used for pipe connection, and make sure there is no

leakage.

•   With the connection part to the indoor unit, please be noted not to impose

pressure on the side of indoor unit pipes.

•  When the declivity of the drain pipe downwards is over 1/100, there should not

be any winding.

•  The total length of the drain pipe when pulled out traversely shall not exceed

20m, when the pipe is over long, a prop stand must be installed to prevent
winding.

• Refer  

to  

the

fi

 gures on the right for the installation of the pipes.

Summary of Contents for YOCC-YOHC 12-60

Page 1: ...t by trained and qualified personnel After unpacking please check the unit carefully for possible damage Before undertaking any work on the unit make sure that the power supply has been disconnected CAUTIONS FOR INSTALLATION Do not store or unpack the unit in a wet area or expose to rain or water It may cause the unit to short circuit and may result electric shocks or fire Do not install in a plac...

Page 2: ...cated to the air conditioner SYSTEM RELOCATION Relocating the air conditioner requires specialized knowledge and skills Please consult the shop where you bought the air conditioner if relocation is necessary for moving or remodelling Select a place which provides the space around the units as shown in the diagram below To prevent interference place at least 1m away Inverter type fluorescent lamp T...

Page 3: ...grille 2 Locate the hanging arm on the hanging screw bolt Refer to Chart 9 Prepare the mounting bolts on the unit Refer to Chart 10 3 Hang the unit on the hanging arm by sliding backward Securely tighten the mounting bolts on both sides Refer to Chart 9 Installation of the outdoor unit in a place exposed regularly to a strong wind Installation of the indoor unit in a place where there is an obstac...

Page 4: ...AL 5x2 0 3x2 0 3x2 0 2x2 0 3x2 0 2x2 0 WEAK ELECTRIC SIGNAL 1 core sheild wire 1x0 5mm2 2 core sheild wire 2x0 5mm2 TYPE 12000 18000 Btu h Cooling Only 24000 36000 Btu h Cooling Only 36000 60000 Btu h Cooling Only POWER PHASE 1 PHASE 1 PHASE 3 PHASE FREQUENCY AND VOLT 220 240V 50Hz 220 240V 50Hz 380V 3N 50Hz CIRCUIT BREAKER FUSE A 40 25 40 20 40 25 INDOOR UNIT POWER WIRING mm2 3x2 5 3x2 5 5x2 5 IN...

Page 5: ...le 3x2 5mm2 3 core cable 3x2 5mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz 3 core cable 3x2 5mm2 3 core cable 3x2 5mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz 1 core sheild wire 1x0 5mm2 3 core cable 3x2 5mm2 3 core cable 3x2 0mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz Chart 27 24000 36000 Btu h 1 PHASE Air Conditioner Link circuit For R 22 Cooling only 3 core cable 3x2 5mm2 3 core ...

Page 6: ...ge evacuate and recharge 2 Determine the cause and replace compressor 3 Remove charge evacuate and recharge 4 Replace it F Clicking sound is heard from the air conditioner In heating or cooling operation any plastic parts may expand or shrink due to a sudden temperature change in this event a clicking sound may occur In heating or cooling operation any plastic parts may expand or shrink due to a s...

Page 7: ...TION FUNCTION Auto Restart Function The unit will automatically restart after loss of the electrical power supply When power is restored the unit operation will restart according to all parameters set before the loss of power ANTI ICE and ANTI OVERHEAT This feature is used to prevent the indoor unit from freezing during cool or dry operation and overheating in heat mode During execution of anti ic...

Page 8: ...d Hi Med Low r min 1 190 1 000 890 1 280 1 190 1 000 1 280 1 190 1 000 1 310 1 200 1 000 1 310 1 200 1 000 1 310 1 200 1 000 1 310 1 200 1 000 820 695 620 820 695 620 Indoor coil Number of rows 2 3 3 3 3 3 3 3 3 Tube pitch a row pitch b mm 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 Fin spacing mm 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 Fin type Hydrophilic aluminum Tube ou...

Reviews: