background image

> 30 cm

20

••

25mm

8

••

13mm

>20mm

285

750

845

590

695

860

351.2

135

235

125

335

330

530

110

62

315

290

301.5

141.5

560.1

163

590

313

895

300

360

960

990

336.4

400

1245

360

940

650

181.4

624

B

C

E

D

A

H

❥✱

  DC Inverter R-410A

MODEL

A

B

C

D

E

H

REMARK

18

840 550 335 360 310 677

R-410A

24

894 590 333 355 302 860

36

990 624 366 396 340 960

48

940 600 376 400 340 1245

❥✱

  YODC-YOJC 30-36

❥✱

  YODC-YOJC 48-60

❥✱

  YODC-YOJC 12

❥✱

  YODC-YOJC 18

❥✱

  YODC-YOJC 24

Outdoor unit

Chart 9

Hanging arm

Hanging
screw bolt

Mounting bolt

D.  Connecting point of refrigerant pipe
 

(D. gas side)

E.  Connecting point of refrigerant pipe
 

(E. Liquid side)

Drain point

Chart 11

Chart 10

Screw nut

Washer

Hanging
screw bolt

Hanging arm

Mounting bolt (max. 40 mm)

Side board

Grille

Hanging arm

  ATTENTION:

The

fi

  gures above are based on model with 18000 Btu/h as rated

capacity, which may differ from the unit you purchased.

The dimension of the unit

Capacity

(Btu/h)

A

B

C

D

E

F

G

H

12000-24000 Btu/h

990

660

206

505

506

907

200

203

36000 Btu/h

1280

660

206

795

506

1195

200

203

48000-60000 Btu/h

1670

680

244

1070

450

1542

200

240

•  Note:  The dimension of 12000 Btu/h and 24000 Btu/h are the same
   

The dimension of 48000 Btu/h and 60000 Btu/h are the same

Chart 8

Chart 7

Installation of the indoor unit at too high > 30 cm
a position.

CEILING INSTALLATION

1. Remove the side board and the grille. (Refer to Chart 8)
  (For models 48000 and 60000 Btu/h, do not remove the grille.)

2. Locate the hanging arm on the hanging screw bolt. (Refer to Chart 9)
  Prepare the mounting bolts on the unit. (Refer to Chart 10)

3. Hang the unit on the hanging arm by sliding backward. Securely tighten the

mounting bolts on both sides. (Refer to Chart 9)

Installation of the outdoor unit in a place
exposed regularly to a strong wind.

Installation of the indoor unit in a place where
there is an obstacle near the air inlet or outlet.

Installation of outdoor units too close or,
blowing discharged air into each other.

Installation in the unit in wrong direction.

Installation of the indoor unit in direct sun light.

INSTALLATION IN THE FOLLOWING PLACES

MAY RESULT IN TROUBLE

INDOOR UNIT INSTALLATION

Installing Ø10 hanging screw bolts. (4 bolts)
•  Please refer to the following

fi

 gure for the distance measurement between the

screw bolts.

•  Please install with Ø10 hanging screw bolts.
•  The handling to the ceiling varies from the constructions, consult the construction

personnels for the speci

fi

 c procedures.

1. The size of the ceiling to be handled ... ... do keep the ceiling

fl

 at. Consolidate

the roof beam for possible vibration.

2. Cut off the roof beam.
3. Strengthen the place cut off, and consolidate the roof beam.
•  Carry out the pipe and line operation in the ceiling after

fi

 nishing the installation

of the main body. While choosing where to start the operation, determine the
direction of the pipes to be drawn out. Especially in case there is a ceiling, position
the refrigerant pipes, drain pipes, indoor & outdoor lines to the connection places
before hanging up the machine.

•  The installation of hanging screw bolts.

Summary of Contents for YOCC-YOHC 12-60

Page 1: ...t by trained and qualified personnel After unpacking please check the unit carefully for possible damage Before undertaking any work on the unit make sure that the power supply has been disconnected CAUTIONS FOR INSTALLATION Do not store or unpack the unit in a wet area or expose to rain or water It may cause the unit to short circuit and may result electric shocks or fire Do not install in a plac...

Page 2: ...cated to the air conditioner SYSTEM RELOCATION Relocating the air conditioner requires specialized knowledge and skills Please consult the shop where you bought the air conditioner if relocation is necessary for moving or remodelling Select a place which provides the space around the units as shown in the diagram below To prevent interference place at least 1m away Inverter type fluorescent lamp T...

Page 3: ...grille 2 Locate the hanging arm on the hanging screw bolt Refer to Chart 9 Prepare the mounting bolts on the unit Refer to Chart 10 3 Hang the unit on the hanging arm by sliding backward Securely tighten the mounting bolts on both sides Refer to Chart 9 Installation of the outdoor unit in a place exposed regularly to a strong wind Installation of the indoor unit in a place where there is an obstac...

Page 4: ...AL 5x2 0 3x2 0 3x2 0 2x2 0 3x2 0 2x2 0 WEAK ELECTRIC SIGNAL 1 core sheild wire 1x0 5mm2 2 core sheild wire 2x0 5mm2 TYPE 12000 18000 Btu h Cooling Only 24000 36000 Btu h Cooling Only 36000 60000 Btu h Cooling Only POWER PHASE 1 PHASE 1 PHASE 3 PHASE FREQUENCY AND VOLT 220 240V 50Hz 220 240V 50Hz 380V 3N 50Hz CIRCUIT BREAKER FUSE A 40 25 40 20 40 25 INDOOR UNIT POWER WIRING mm2 3x2 5 3x2 5 5x2 5 IN...

Page 5: ...le 3x2 5mm2 3 core cable 3x2 5mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz 3 core cable 3x2 5mm2 3 core cable 3x2 5mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz 1 core sheild wire 1x0 5mm2 3 core cable 3x2 5mm2 3 core cable 3x2 0mm2 OUTDOOR UNIT INDOOR UNIT POWER 220 240V 50Hz Chart 27 24000 36000 Btu h 1 PHASE Air Conditioner Link circuit For R 22 Cooling only 3 core cable 3x2 5mm2 3 core ...

Page 6: ...ge evacuate and recharge 2 Determine the cause and replace compressor 3 Remove charge evacuate and recharge 4 Replace it F Clicking sound is heard from the air conditioner In heating or cooling operation any plastic parts may expand or shrink due to a sudden temperature change in this event a clicking sound may occur In heating or cooling operation any plastic parts may expand or shrink due to a s...

Page 7: ...TION FUNCTION Auto Restart Function The unit will automatically restart after loss of the electrical power supply When power is restored the unit operation will restart according to all parameters set before the loss of power ANTI ICE and ANTI OVERHEAT This feature is used to prevent the indoor unit from freezing during cool or dry operation and overheating in heat mode During execution of anti ic...

Page 8: ...d Hi Med Low r min 1 190 1 000 890 1 280 1 190 1 000 1 280 1 190 1 000 1 310 1 200 1 000 1 310 1 200 1 000 1 310 1 200 1 000 1 310 1 200 1 000 820 695 620 820 695 620 Indoor coil Number of rows 2 3 3 3 3 3 3 3 3 Tube pitch a row pitch b mm 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 25 4 22 Fin spacing mm 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 1 7 Fin type Hydrophilic aluminum Tube ou...

Reviews: