![background image](http://html1.mh-extra.com/html/york/yoca-yoha-12/yoca-yoha-12_service-manual_3611307017.webp)
Packing
(W*H*D)
mm
1764×760×330
1764×760×330
Net/Gross weight
kg
52/59
52/59
Model
YDK65-6F(YDK65-6F-WL)
YDK65-6F(YDK65-6F-WL)
Input
W
148+148
118/108/101
Capacitor
uF
3.5x2 uF/450V
2.5uF/450V
Outdoor fan
motor
Speed (hi/lo)
r/min
800
800
Number of rows
2
2
Tube pitch(a)x row pitch(b)
mm
25.4X22
25.4X22
Fin spacing
mm
1.5
1.7
Fin type
UnHydrophilic aluminium
Hydrophilic aluminum
Tube outer dia.and type
mm
Ø
9.53, innergroove tube
Ø
9.53, inner groove tube
Coil length x height x width
mm
897*1220*44
897×1220×44
Outdoor coil
Number of circuits
4
4
Outdoor air flow
m3/h
6000
6000
Outdoor noise level
dB(A)
65
62
Dimension(W*H*D)
mm
940*1245*340
940*1245*340
Packing (W*H*D)
mm
1058*1370*435
1058*1370*435
Outdoor unit
Net/Gross weight
kg
110/125
114/135
Refrigerant recharge weight
g
4400
5000
Design pressure
MPa
2.6/1.2
2.8/1.2
Liquid side/ Gas side
mm
12
Ø
Ø
Ø
Ø
.7(1/2")- 19(3/4")
12.7(1/2")-
19(3/4")
Max. pipe length
m
30
30
Refrigerant
piping
Max. difference in level
m
15
15
Draining pipe dimension
mm
DN20
DN20
Operation temp
ºC
17~30
17~30
Ambient temp
ºC
-7~45
-7~45
Application area
m2
95~120
95~120
Qty’per 20’/ 40’/40HQ
Pieces
27/55/55
27/55/55
Notes:
1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. Piping: 7.5m(horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal)
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an
anechoic room.