background image

owner’s manual

7

Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air 
smooth.
Close doors and windows.
Make curtains in order to shelter from 
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage and rightly recharge 
refrigerant.

Air flowing normally but 
completely can't  cooling

Units start or stop frequently

Low cooling effect

Low heating effect

Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted 
or other problem of controller.

Temperature is not set correctly.
Be in 3 minutes protection of 
compressor.

Refrigerant is too little or too much.
Air or no concretingc gas in the 
refrigerating circuit.
Compressor is malfunction.
Voltage is too high or too low.
System circuit is blocked.

Outdoor unit and indoor unit heat 
exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor/outdoor units is 
blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Outdoor temp. is too high.
Leakage of refrigerant or lack of 
refrigerant.

Wait for the comeback of power.
Switch on the power.
ReplLocation:
Replace the batterises or check the 
controller.

Set the temperature properly.
Wait.

Check leakage, and rightly recharge 
refrigerant.
Vacuum and recharge refrigerant.
Maintenance or change compressor.
Install manostat.
Find reasons and solution.

Use heating device.
Close doors and windows.
Check leakage and rightly recharge 
refrigerant.

Outdoor temperature is lower  than 7 C 
Doors and windows not completely 
closed.
Leakage of refrigerant or  lack of 
refrigerant.

Solution

Symptoms

Causes

Unit does not start 

Table 8-2

Table 8-1

12

Malfunction

Running lamp

Timer lamp

Defrosting lamp

Alarm lamp

In-outdoor unit communication 
checking channel is abnormal

Room temperature senson
checking channel is abnormal

Collision model malfunction

Outdoor unti malfunction

Water-level alarm malfunction

LED
flash

LED
flash

LED
flash

LED
flash

     LED
Slow flash

Summary of Contents for YMFFZC018-024BAM-AFX

Page 1: ...Read this manual before installation and operation Make sure that it is well kept for later reference Floor Ceiling R 410A 50Hz USER S MANUAL YMFFZC018 024BAM AFX YMFFZH018 060BAM N A B FX ...

Page 2: ...NDOOR UNIT OUTDOOR UNIT 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 9 7 8 RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED 0 LOCK C H AUT O CO OL DR Y HEA T FAN TEM P SET CLOC K SET HO...

Page 3: ...ion systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the ...

Page 4: ... the unit or under the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Do not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out The appliance is not intended for use by young children or infirm persons without supervision 2 TEMPORARY OPERATIONS The air co...

Page 5: ...ximately 3 minutes when it restarts immedi ately after operation Power failure Power failure during operation will stop the unit completely The OPERATION lamp on the indoor unit will start flashing when power is restored To restart operation push the ON OFF button on the remote controller Lighting or a car wireless telephone operating nearby may cause the unit to malfunction Disconnect the unit wi...

Page 6: ...king efficiency of the air conditioner may greatly decrease Therefore the filter must be cleaned once two weeks during long time usage If the air conditioner is installed in a dust place clean the the air filter frequent If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting Before you clean the air conditioner be s...

Page 7: ...remely contaminated the temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service erson When the system is changed over to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted A continuous low shah sound ...

Page 8: ...leaks from indoor unit Other malfunctions 8 TROUBLESHOOTING If one of the following malfunctions occur stop operation shut off the power and contact with your dealer If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 2 8 1 Troubles and causes of air condi...

Page 9: ...let of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refr...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ......

Page 12: ...QS01U 006AW ...

Page 13: ...www johnsoncontrols com UFEJZ AM 110802 2010 Johnson Controls Inc Johnson Controls reserve the right to change product features without prior notice ...

Reviews: