1.    IMPORTANT SAFETY INFORMATION

To prevent injury to the user or other people and property 
damage, the following  instructions must be followed. Incorrect 
operation due to ignoring of instructions may cause harm or 
damage. 

Ask your dealer for installation of the air conditioner. 

Incomplete installation performed by yourself may result in a 
water leakage, electric shock, and fire. 

Ask your dealer for improvement, repair, and 
maintenance.

 

Incomplete improvement, repair, and maintenance may result 
in a water leakage, electric shock, and fire. 

In order to avoid electric shock, fire or injury, or if you 
detect any abnormality such as smell of fire, turn off the 
power supply and call your dealer for instructions.

Never let the indoor unit or the remote controller get wet.

 

It may cause an electric shock or a fire.

Never press the button of the remote controller with a 
hard, pointed object.

 

The remote controller may be damaged. 

Never replace a fuse with that of wrong rated current or 
other wires when a fuse blows out. 

Use of wire or copper wire may cause the unit to break down 
or cause a fire.

It is not good for your health to expose your body to the 
air flow for a long time.

Do not insert fingers, rods or other objects into the air 
inlet or outlet.

 

When the fan is rotating at high speed, it will cause injury. 

Never use a flammable spray such as hair spray, lacquer 
or paint near the unit. 

It may cause a fire. 

Never touch the air outlet or the horizontal blades while 
the swing flap is in operation. 

Fingers may become caught or the unit may break down. 

Never put any objects into the air inlet or outlet.

 

Objects touching the fan at high speed can be dangerous.

Never inspect or service the unit by yourself.

 

Ask a qualified service person to perform this work. 

Do not dispose this product as unsorted municipal 
waste. Collection of such waste separately for special 
treatment is necessary.

Do not dispose of electrical appliances as unsorted 
municipal waste, use separate collection facilities.

Contact you local government for information regarding the 
connection systems available.

If electrical appliances are disposed of in landfills or 
dumps, hazardous substances can leak into the 
groundeater and get into the food chain, damaging your 
health and well-being.

To prevent refrigerant leak, contact your dealer. 

When the system is installed and runs in a small room, it is 
required to keep the concentration of the refrigerant, if by any 
chance coming out, below the limit. Otherwise, oxygen in the 
room may be affected, resulting in a serious accident. 

The refrigerant in the air conditioner is safe and normally 
does not leak. 

If the refrigerant leaks in the room, contact with a fire of a 
burner, a heater or a cooker may result in a harmful gas.

Turn off any combustible heating devices, ventilate the 
room, and contact the dealer where you purchased the 
unit. 

Do not use the air conditioner until a service person confirms 
that the portion where the refrigerant leaks is repaired. 

Do not use the air conditioner for other purposes. 

In order to avoid any quality deterioration, do not use the unit 
for cooling precision instruments, food, plants, animals or 
works of art. 

Before cleaning, be sure to stop the operation, turn the 
breaker off or pull out the supply cord. 

Otherwise, an electric shock and injury may result. 

In order to avoid electric shock or fire, make sure that an 
earth leak detector is installed.

Be sure the air conditioner is grounded.

 

In order to avoid electric shock, make sure that the unit is 
grounded and that the earth wire is not connected to gas or 
water pipe, lightning conductor or telephone earth wire.

In order to avoid injury, do not remove the fan guard of 
the outdoor unit.

The safety precautions listed are divided into two categories. In either
case,  important   safety  information  is  listed  which  must   be  read.  

 

 

 

 

 

 

 

 

   

 

 

 

 

CAUTION

Failure to observe a caution may result in injury or damage 
to the equipment.

Failure  to  observe  a  warning  may  result  in  death. The
appliance  shall  be  installed  in  accordance  with national 
wiring regulations.

CONTENTS

PAGE

IMPORTANT SAFETY INFORMATION........................................................1
TEMPORARY  OPERATIONS.....................................................................2
AIR CONDITIONER OPERATIONS AND PERFORMANCE............................3
HINTS FOR ECONOMICAL OPERATION.....................................................3
ADJUSTING AIR FLOW DIRECTION.........................................................4
MAINTENANCE........................................................................................4
FOLLOWING SYMPTOMS ARE NOT AIR CONDITIONER TROUBLES.........5
TROUBLESHOOTING................................................................................6

WARNING

WARNING

CAUTION

Summary of Contents for YMFFZC018-024BAM-AFX

Page 1: ...Read this manual before installation and operation Make sure that it is well kept for later reference Floor Ceiling R 410A 50Hz USER S MANUAL YMFFZC018 024BAM AFX YMFFZH018 060BAM N A B FX ...

Page 2: ...NDOOR UNIT OUTDOOR UNIT 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 9 7 8 RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED 0 LOCK C H AUT O CO OL DR Y HEA T FAN TEM P SET CLOC K SET HO...

Page 3: ...ion systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the ...

Page 4: ... the unit or under the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Do not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out The appliance is not intended for use by young children or infirm persons without supervision 2 TEMPORARY OPERATIONS The air co...

Page 5: ...ximately 3 minutes when it restarts immedi ately after operation Power failure Power failure during operation will stop the unit completely The OPERATION lamp on the indoor unit will start flashing when power is restored To restart operation push the ON OFF button on the remote controller Lighting or a car wireless telephone operating nearby may cause the unit to malfunction Disconnect the unit wi...

Page 6: ...king efficiency of the air conditioner may greatly decrease Therefore the filter must be cleaned once two weeks during long time usage If the air conditioner is installed in a dust place clean the the air filter frequent If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting Before you clean the air conditioner be s...

Page 7: ...remely contaminated the temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service erson When the system is changed over to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted A continuous low shah sound ...

Page 8: ...leaks from indoor unit Other malfunctions 8 TROUBLESHOOTING If one of the following malfunctions occur stop operation shut off the power and contact with your dealer If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 2 8 1 Troubles and causes of air condi...

Page 9: ...let of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refr...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ......

Page 12: ...QS01U 006AW ...

Page 13: ...www johnsoncontrols com UFEJZ AM 110802 2010 Johnson Controls Inc Johnson Controls reserve the right to change product features without prior notice ...

Reviews: