background image

owner’s manual

4

5.    ADJUSTING AIR FLOW DIRECTION

Auto-swing

Press SWING button, the louver will swing up and down  
automatically.

Manual Swing

Adjust the louver to achieve better cooling/heating effects  
when cooling /heating. 

When cooling

Adjust the louver horizontally.

When heating

Adjust the louver downwards. (vertically)

Fig. 5-1

Fig. 5-2

Fig. 5-3

6.    MAINTENANCE

Maintenance after a long stop period 

(eg. at the beginning of the season)

 

Maintenance before a long stop period

 

(eg. at the end of the season)

         

Check and remove everything that might be blocking inlet 
and outlet vents of indoor units and outdoor units.

Clean air filters and casings of indoor units. 
Refer to "Cleaning the air filter" for details on how  to 
proceed and make sure to install cleaned air filters back in 
the same position. 

Turn on the power at least 12 hours before operating the 
unit in order to ensure smoother operation. As soon as he 
power is turned on, the remote controller  displays appear.

Let the indoor units run in fan only operation for about half 
a day in order to dry the interior of the units.

Clean air filters and casings of indoor units. Refer to " 
Cleaning the air filter" for details on how to proceed and 
make sure to install cleaned air filters back in the same 
position. 

Cleaning the air filter

The air filter can prevent the dust or other particulate from 
going inside. In case of blockage of the filter, the working 
efficiency of the air conditioner may greatly decrease.
Therefore, the filter must be cleaned once two weeks 
during long time usage.

If the air conditioner is installed in a dust place, clean the 
the air filter frequent.

If the accumulated dust is too heavy to be cleaned, please 
replace the filter with a new one(replaceable air filter is an 
optional fitting).

Before you clean the air conditioner, be sure the power 
supply is off.

Check if the wiring is not broken off or disconnected.

Use a dry cloth to wipe the indoor unit and remote 
controller.

A wet cloth may be used to clean the indoor unit if it is 
very dirty.

Never use a damp cloth on the remote controller.

Do not use a chemically-treted duster for wiping or leave 
such material on the unit for long.
it may damage or fade the surface of the unit.

Do not use benzine, thinner, polishing powder, or similar 
solvents for cleaning. 
These may cause the plastic surface to crack or deform.

Do not dry out the air filter under direct sunshine or with fire.

           14-16KW

    

1

          3.2-10.5KW

Open the air intake.

(Refer to Fig.6-1)

Take out the air filter.

(Refer to Fig.6-2)

Clean the air cleaning filter with water or vacuum cleaer,then 
dry it in cool place.
Re-install the air filter in the reverse order of 

Fig.6-2.

Directly pull out the air filter from air inlet as indicated in 

Fig.6-3.

 

Clean the air cleaning filter with water or vacuum cleaner, 
then dry it in cool place.
Re-install the air filter in the reverse order of 

Fig.6-3.

The air-in side should face up when using vacuum cleaner.

The air-in side should face down when using water. 

NOTE

CAUTION

CAUTION

Summary of Contents for YMFFZC018-024BAM-AFX

Page 1: ...Read this manual before installation and operation Make sure that it is well kept for later reference Floor Ceiling R 410A 50Hz USER S MANUAL YMFFZC018 024BAM AFX YMFFZH018 060BAM N A B FX ...

Page 2: ...NDOOR UNIT OUTDOOR UNIT 1 2 3 5 4 7 6 8 8 8 8 8 8 9 9 7 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail NOTE OR 9 7 8 RESE T TIM E ON TIM E OFF CLO CK SW ING AIR DIRE CTIO N OK ECO SW ING MO DE FAN SPE ED 0 LOCK C H AUT O CO OL DR Y HEA T FAN TEM P SET CLOC K SET HO...

Page 3: ...ion systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant if by any chance coming out below the ...

Page 4: ... the unit or under the indoor unit It may cause incomplete combustion or deformation of the unit due to the heat Do not install the air conditioner at any place where flammable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out The appliance is not intended for use by young children or infirm persons without supervision 2 TEMPORARY OPERATIONS The air co...

Page 5: ...ximately 3 minutes when it restarts immedi ately after operation Power failure Power failure during operation will stop the unit completely The OPERATION lamp on the indoor unit will start flashing when power is restored To restart operation push the ON OFF button on the remote controller Lighting or a car wireless telephone operating nearby may cause the unit to malfunction Disconnect the unit wi...

Page 6: ...king efficiency of the air conditioner may greatly decrease Therefore the filter must be cleaned once two weeks during long time usage If the air conditioner is installed in a dust place clean the the air filter frequent If the accumulated dust is too heavy to be cleaned please replace the filter with a new one replaceable air filter is an optional fitting Before you clean the air conditioner be s...

Page 7: ...remely contaminated the temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service erson When the system is changed over to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted A continuous low shah sound ...

Page 8: ...leaks from indoor unit Other malfunctions 8 TROUBLESHOOTING If one of the following malfunctions occur stop operation shut off the power and contact with your dealer If the system does not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures See in Table 8 2 8 1 Troubles and causes of air condi...

Page 9: ...let of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power ReplLocation Replace the batterises or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refr...

Page 10: ...emote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an e...

Page 11: ......

Page 12: ...QS01U 006AW ...

Page 13: ...www johnsoncontrols com UFEJZ AM 110802 2010 Johnson Controls Inc Johnson Controls reserve the right to change product features without prior notice ...