036-21570-002 Rev. D (0605)
4
Unitary Products Group
**
Refer to Quick Selection Chart for specific furnace match-up.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
TOTAL
CAPACITY
SENSIBLE
CAPACITY
SEER
W/O TXV
SEER
W/ TXV
EER
1 PH 12 SEER HP WITH N1AH / G2FD
YMA02411
N1AHB08
2,5,8,10 17
G2FD030(S,H)17(T)
800
24.0
18.8
12.00
12.00
10.90
N1AHB12
2,5,8,10 17
G2FD030(S,H)17(T)
800
24.0
18.8
12.00
12.00
10.90
YMA03011
N1AHB08
2,5,8,10 17
G2FD030(S,H)17(T)
1000
30.0
23.0
12.00
12.00
11.10
N1AHB12
2,5,8,10 17
G2FD030(S,H)17(T)
1000
30.0
23.0
12.00
12.00
11.10
N1AHB08
2,5,8,10 17
G2FD036(S,H)17(T)
1200
35.2
27.2
12.00
12.00
11.05
YMA03611
N1AHB12
2,5,8,10 17
G2FD036(S,H)17(T)
1200
35.2
27.2
12.00
12.00
11.05
N1AHC16
5,8,10,15,20 21
G2FD036(S,H)21(T)
1200
35.6
28.0
12.00
12.00
11.30
YMA04211
N1AHC16
5,8,10,15,20 21
G2FD048(S,H)21(T)
1400
42.0
32.8
12.00
12.00
10.70
N1AHD20
8,10,15,20,25,30
24 G2FD048(S,H)24(T)
1400
42.0
32.8
12.00
12.00
10.70
YMA04811
N1AHD20
8,10,15,20,25,30
24 G2FD060(S,H)24(T)
1600
46.0
35.6
-
12.00
10.20
N1AHD20
8,10,15,20,25,30
24 G2FD061H24 1600
46.0
36.0
-
12.00
10.25
YMA06011
N1AHD20 8,10,15,20,25,30
24
G2FD060(S,H)24(T)
1800
54.0 42.2
11.70
-
10.50
N1AHD20 8,10,15,20,25,30
24
G2FD061H24
1800
54.5 42.4
12.00
-
10.55
1 PH 12 SEER HP / N1VS - VARIABLE SPEED
YMA02411
N1VSB12
2,5,8,10 17
G2FD030(S,H)17(T)
775
24.2
18.5
13.00
13.00
11.95
YMA03011
N1VSB12
2,5,8,10 17
G2FD030(S,H)17(T)
1000
30.2
22.8
13.00
13.00
11.95
YMA03611
N1VSB12
2,5,8,10 17
G2FD036(S,H)17(T)
1200
35.4
26.8
12.50
12.50
11.65
N1VSC16
5,8,10,15,20 21
G2FD036(S,H)21(T)
1200
36.0
27.6
13.00
13.00
12.20
YMA04211
N1VSC16
5,8,10,15,20 21
G2FD048(S,H)21(T)
1380
42.5
32.4
13.00
13.00
11.45
N1VSD20
8,10,15,20,25,30
24 G2FD048(S,H)24(T)
1350
42.5
32.0
13.00
13.00
11.40
YMA04811
N1VSD20
8,10,15,20,25,30
24 G2FD060(S,H)24(T)
1600
46.0
35.0
-
12.50
10.65
N1VSD20
8,10,15,20,25,30
24 G2FD061H24
1600
46.5
35.4
-
12.50
10.70
YMA06011
N1VSD20 8,10,15,20,25,30
24
G2FD060(S,H)24
1780
53.5 40.6
12.00
-
10.65
N1VSD20 8,10,15,20,25,3
24
G2FD061H24
1780
54.5 41.4
12.10
-
10.85
1 PH 12 SEER HP / F2RP / RC / FP / FC / FV
3,4
YMA02411
F2RC/F2FC036
5,8,10,15 18
-
800 24.0
18.8 12.00
12.00
10.90
F2RP/F2FP/F3FP024
5,8,10,15 18
-
800 23.6
18.6 12.00
12.00
10.90
F2RP/F2FP/F3FP030
5,8,10,15 18
-
800 24.0
18.8 12.00
12.00
10.90
YMA03011
F2RC/F2FC036
5,8,10,15 21
-
1000 29.6
22.2 12.00
12.00
11.05
F2RP/F2FP/F3FP030
5,8,10,15 21
-
1000 29.6
22.2 12.00
12.00
11.05
F2FP/F3FP040
5,8,10,15 21
-
1200 36.0
27.2 12.00
12.00
11.30
YMA03611
F2RP/F2FP/F3FP036
5,8,10,15 21
-
1200 35.8
27.0 12.00
12.00
11.20
F2RP/F2FP/F3FP042
5,8,10,15 21
-
1200 36.0
27.2 12.00
12.00
11.30
YMA04211
F2FP048
5,8,10,15,20,25 24
-
1400
41.5
31.8
12.00 12.00 10.55
F2FP/F3FP060
8,10,15,20,25 24
-
1600
45.5
34.2
-
11.50
10.00
YMA04811
F2FP045
5,8,10,15 24
-
1600 45.5
34.5
-
12.00
10.20
YMA06011
F2FP060 8,10,15,20,25
24 -
1800
53.0
40.4
11.25
-
10.25
F2FV060 8,10,15,20,25
24 -
1780
54.0
40.8
12.00
-
10.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8
0
°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2
Single phase units require single phase 2HK heaters.
3
To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
.
models. All ratings remain the same.
4
FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard.