
JOHNSON CONTROLS
FORM 150.72-EG6 (516)
44
YLAA VOLT
HZ
MCA
MIN
N/F
DISC
SW
MIN
DUAL
ELEM
FUSE
& CB
MAX
DUAL
ELEM
CB
SYSTEM # 1
COMPR 1
COMPR 2
COMPR 3
STD FLOW FANS
RLA LRA RLA LRA RLA
LRA QTY FLA
LRA
58
208
60
276
400
300
300
57.7
284
57.7
284
2
7.6
44
230
60
275
400
300
300
57.7
330
57.7
330
2
7.4
37
380
60
149
200
175
175
30.9
192
30.9
192
2
4.5
23.1
460
60
130
200
150
150
26.9
180
26.9
180
2
4
19
575
60
103
150
110
110
21.5
132
21.5
132
2
2.9
15.3
65
208
60
306
400
350
350
48.5
249
48.5
249
48.5
249
2
7.6
44
230
60
305
400
350
350
48.5
288
48.5
288
48.5
288
2
7.4
37
380
60
170
250
200
200
27.6
159
27.6
159
27.6
159
2
4.5
23.1
460
60
150
200
175
175
24.4
145
24.4
145
24.4
145
2
4
19
575
60
112
150
125
125
17.4
109
17.4
109
17.4
109
2
2.9
15.3
70
208
60
334
400
350
350
48.5
249
48.5
249
48.5
249
2
7.6
44
230
60
333
400
350
350
48.5
249
48.5
249
48.5
249
2
7.4
37
380
60
191
250
225
225
27.6
159
27.6
159
27.6
159
2
4.5
23.1
460
60
169
200
175
175
24.4
145
24.4
145
24.4
145
2
4
19
575
60
120
150
125
125
17.4
109
17.4
109
17.4
109
2
2.9
15.3
80
208
60
363
600
400
400
57.7
284
57.7
284
57.7
284
2
7.6
44
230
60
363
600
400
400
57.7
330
57.7
330
57.7
330
2
7.4
37
380
60
201
250
225
225
30.9
192
30.9
192
30.9
192
2
4.5
23.1
460
60
177
250
200
200
26.9
180
26.9
180
26.9
180
2
4
19
575
60
134
200
150
150
21.5
132
21.5
132
21.5
132
2
2.9
15.3
81
208
60
363
400
400
400
57.7
284
57.7
284
57.7
284
2
7.6
44
230
60
363
400
400
400
57.7
330
57.7
330
57.7
330
2
7.4
37
380
60
201
250
225
225
30.9
192
30.9
192
30.9
192
2
4.5
23.1
460
60
177
250
200
200
26.9
180
26.9
180
26.9
180
2
4
19
575
60
134
200
150
150
21.5
132
21.5
132
21.5
132
2
2.9
15.3
89
208
60
391
600
450
450
57.7
284
57.7
284
57.7
284
2
7.6
44
230
60
390
600
450
450
57.7
330
57.7
330
57.7
330
2
7.4
37
380
60
211
250
250
250
30.9
192
30.9
192
30.9
192
2
4.5
23.1
460
60
184
250
200
200
26.9
180
26.9
180
26.9
180
2
4
19
575
60
146
200
150
150
21.5
132
21.5
132
21.5
132
2
2.9
15.3
92
208
60
406
600
450
450
57.7
284
57.7
284
57.7
284
3
7.6
44
230
60
405
600
450
450
57.7
330
57.7
330
57.7
330
3
7.4
37
380
60
220
400
250
250
30.9
192
30.9
192
30.9
192
3
4.5
23.1
460
60
192
250
225
225
26.9
180
26.9
180
26.9
180
3
4
19
575
60
152
200
150
150
21.5
132
21.5
132
21.5
132
3
2.9
15.3
100
208
60
450
600
500
500
57.7
284
57.7
284
57.7
284
2
7.6
44
230
60
449
600
500
500
57.7
330
57.7
330
57.7
330
2
7.4
37
380
60
260
400
300
300
30.9
192
30.9
192
30.9
192
2
4.5
23.1
460
60
220
400
250
250
26.9
180
26.9
180
26.9
180
2
4
19
575
60
175
250
200
200
21.5
132
21.5
132
21.5
132
2
2.9
15.3
Electrical Data Without Pumps
NOTES:
1. Reference PIN 59 for pump models.
2. Use this table along with Pump Electrical Data
on page 44
to determine electrical data of the unit plus the pump.
3. Does not include the Control Transformer
on page 41
)
Summary of Contents for YLAA
Page 4: ...JOHNSON CONTROLS FORM 150 72 EG6 516 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 35: ...FORM 150 72 EG6 516 JOHNSON CONTROLS 35 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 48: ...JOHNSON CONTROLS FORM 150 72 EG6 516 48 Wiring Diagram ...
Page 49: ...FORM 150 72 EG6 516 JOHNSON CONTROLS 49 LD18444 Wiring Diagram Cont d ...