![background image](http://html1.mh-extra.com/html/york/yhjd18s41s7/yhjd18s41s7_technical-manual_913536053.webp)
Johnson Controls Unitary Products
53
HEATING CAPACITY - With High Efficiency Motor Furnaces - CANADA ONLY (Continued)
UNIT
MODEL
FURNACE
MODEL
COIL
1
MODEL
HEATING
2
47°F
17°F
HSPF
MBH
COP
KW
MBH
COP
KW
STD
14 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
3
YHJD48S41S7
TM8X080C16MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM8X100C16MP11
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM8X100C16MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM8X100C20MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM8X120C20MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM9E080C16MP11
FC/MC/PC60D
46.0
3.60
3.74
24.8
2.32
3.13
7.75
YHJD48S41S7
TM9E080C16MP11
FC/MC62D
45.0
3.26
4.04
25.2
2.36
3.13
8.00
YHJD48S41S7
TM9E080C16MP11
FC/PC60C
46.0
3.60
3.74
24.8
2.32
3.13
7.75
YHJD48S41S7
TM9E100C16MP11
FC/MC/PC60D
46.0
3.60
3.74
24.8
2.32
3.13
7.75
YHJD48S41S7
TM9E100C16MP11
FC/MC62D
45.0
3.26
4.04
25.2
2.36
3.13
8.00
YHJD48S41S7
TM9E100C16MP11
FC/PC60C
46.0
3.60
3.74
24.8
2.32
3.13
7.75
YHJD48S41S7
TM9E100C20MP11
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TM9E120D20MP11
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX080C16MP11
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX080C16MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX100C16MP11
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX100C16MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX100C20MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
TMLX120C20MP11
FC/PC60C
46.0
3.60
3.74
24.4
2.40
2.98
8.00
YHJD48S41S7
Y*(8,L)C*C16
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.38
3.00
8.00
YHJD48S41S7
Y*(8,L)C*C16
FC/PC60C
46.0
3.60
3.74
24.4
2.38
3.00
8.00
YHJD48S41S7
Y*9C*C16
FC/MC/PC60D
46.0
3.60
3.74
24.8
2.34
3.11
8.00
YHJD48S41S7
Y*9C*C16
FC/MC62D
45.0
3.28
4.02
25.0
2.38
3.08
8.00
YHJD48S41S7
Y*9C*C16
FC/PC60C
46.0
3.60
3.74
24.8
2.34
3.11
8.00
YHJD48S41S7
Y*9C*C20
FC/MC/PC60D
46.0
3.60
3.74
24.6
2.38
3.03
8.00
YHJD48S41S7
Y*9C*C20
FC/MC62D
45.0
3.32
3.97
24.8
2.42
3.00
8.00
YHJD48S41S7
Y*9C*C20
FC/PC60C
46.0
3.60
3.74
24.6
2.38
3.03
8.00
YHJD48S41S7
Y*9C*D20
FC/MC/PC60D
46.0
3.60
3.74
24.4
2.38
3.00
8.00
1. Rated CFM same as for cooling.
2. Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping
and no supplemental electric heat operation.
3. High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input
during the same period.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
— = Not Applicable.
571209-YTG-F-0615