34
Johnson Controls Unitary Products
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
YHJD60S41S7
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
IDCFM
1650
1850
2050
ID DB (°F)
80
80
75
80
80
80
80
75
80
80
80
80
75
80
80
ID WB (°F)
57
62
62
67
72
57
62
62
67
72
57
62
62
67
72
65
T.C.
57.5
60.5
60.5
66.0
72.0
59.4
61.6
61.6
67.1
73.0
61.2
62.7
62.6
68.2
74.0
S.C.
57.1
52.5
44.9
44.2
35.6
58.9
55.6
46.8
46.2
36.7
60.8
58.6
48.8
48.2
37.7
KW
3.59
3.62
3.62
3.68
3.75
3.68
3.70
3.71
3.76
3.83
3.78
3.79
3.79
3.85
3.92
75
T.C.
55.4
57.7
57.7
63.0
68.8
57.1
58.6
58.6
64.0
69.7
58.8
59.6
59.5
65.0
70.7
S.C.
55.0
51.3
43.6
42.9
34.2
56.7
54.0
45.5
44.9
35.3
58.4
56.8
47.4
46.8
36.4
KW
4.02
4.05
4.05
4.11
4.18
4.11
4.13
4.13
4.19
4.27
4.21
4.22
4.21
4.28
4.36
85
T.C.
53.3
54.8
54.9
60.1
65.6
54.9
55.7
55.6
61.0
66.5
56.5
56.5
56.3
61.8
67.4
S.C.
52.9
50.0
42.2
41.6
32.8
54.5
52.5
44.1
43.6
33.9
56.1
54.9
46.1
45.5
35.0
KW
4.45
4.47
4.47
4.54
4.61
4.55
4.56
4.56
4.62
4.70
4.64
4.64
4.64
4.71
4.79
95
T.C.
51.2
51.9
52.0
57.1
62.4
52.6
52.7
52.6
57.9
63.2
54.1
53.5
53.1
58.6
64.0
S.C.
50.8
48.8
40.9
40.4
31.4
52.3
50.9
42.8
42.2
32.5
53.7
53.1
44.7
44.1
33.7
KW
4.89
4.90
4.90
4.97
5.05
4.98
4.98
4.98
5.06
5.14
5.07
5.07
5.06
5.14
5.23
105
T.C.
48.5
48.3
48.6
53.4
58.5
49.8
49.5
49.1
54.0
59.1
51.2
50.6
49.5
54.6
59.7
S.C.
48.1
46.6
39.4
38.8
29.9
49.5
48.4
41.3
40.7
31.0
50.8
50.2
43.1
42.6
32.1
KW
5.43
5.42
5.43
5.50
5.58
5.52
5.52
5.51
5.59
5.67
5.62
5.62
5.60
5.68
5.76
115
T.C.
45.8
44.8
45.2
49.6
54.6
47.0
46.3
45.5
50.1
55.0
48.3
47.7
45.9
50.6
55.5
S.C.
45.5
44.5
37.9
37.3
28.5
46.7
45.9
39.7
39.2
29.5
47.9
47.4
41.6
41.1
30.5
KW
5.97
5.95
5.97
6.04
6.12
6.07
6.06
6.05
6.12
6.21
6.17
6.16
6.13
6.21
6.29
125
T.C.
43.1
41.2
41.7
45.9
50.7
44.2
43.0
42.0
46.2
50.9
45.4
44.9
42.3
46.5
51.2
S.C.
42.8
41.2
36.3
35.7
27.0
43.9
43.0
38.2
37.6
28.0
45.0
44.5
40.0
39.5
28.9
KW
6.51
6.48
6.50
6.57
6.65
6.62
6.59
6.58
6.66
6.74
6.72
6.71
6.66
6.74
6.82
NOTE:
ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (O INDOOR).
Green
shaded cells are ACCA (TVA) conditions.
Blue
shaded cells are AHRI conditions.
Multipliers for determining the performance with other indoor sections.
NOTE:
For dry bulb temperatures different than those listed (between 73-87 °F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
Some of the combinations shown in these multiplier tables are not valid for use in the U.S.A. Please see the Capacity
Tables in the front of this Technical Guide for US matches, and verify matchups in the online AHRI directory at
www.ahridirectory.org
before sale. The matches shown at the end of this Technical Guide are for use in Canda Only.
Air Handlers
Coils
T.C.
S.C.
KW
–
FC/MC62D
0.97
1.01
1.01
–
FC64D
0.97
1.02
1.01
AHE60D
–
0.98
1.01
0.94
AHV60D
–
0.98
0.96
0.94
MV20D
FC/MC62D
0.98
1.01
0.94
MV20D
FC64D
0.98
0.99
0.94
MX20DN21
FC/MC62D
0.98
1.03
0.94
MX20DN21
FC64D
0.98
1.02
0.94
Furnaces
Coils
T.C.
S.C.
KW
T*(8,L)V*C20
FC/MC62D
0.98
0.93
0.94
T*(8,L)V*C20
FC64D
0.98
0.97
0.94
T*9V*C20
FC/MC62D
0.98
0.95
0.94
T*9V*C20
FC64D
0.98
0.95
0.94
T*9V*D20
FC/MC62D
0.98
0.92
0.94
T*9V*D20
FC64D
0.98
0.95
0.94
TM8X100C20MP11
FC/MC62D
0.98
0.92
0.94
TM8X100C20MP11
FC64D
0.98
0.95
0.94
Furnaces
Coils
T.C.
S.C.
KW
TM8X120C20MP11
FC/MC62D
0.98
0.95
0.94
TM8X120C20MP11
FC64D
0.98
0.92
0.94
TM9E100C20MP11
FC/MC62D
0.98
0.96
0.93
TM9E100C20MP11
FC64D
0.98
0.95
0.94
TM9E120D20MP11
FC/MC62D
0.98
0.97
0.93
TM9E120D20MP11
FC64D
0.98
0.92
0.94
TMLX100C20MP11
FC/MC62D
0.98
0.92
0.94
TMLX100C20MP11
FC64D
0.98
0.97
0.94
TMLX120C20MP11
FC/MC62D
0.98
0.95
0.94
TMLX120C20MP11
FC64D
0.98
0.96
0.94
Y*(8,L)C*C20
FC/MC62D
0.98
0.93
0.94
Y*(8,L)C*C20
FC64D
0.98
0.97
0.94
Y*9C*C20
FC/MC62D
0.98
0.95
0.94
Y*9C*C20
FC64D
0.98
0.95
0.94
Y*9C*D20
FC/MC62D
0.98
0.92
0.94
Y*9C*D20
FC64D
0.98
0.95
0.94
571209-YTG-F-0615