FORM 150.63-EG1
Ratings -
HFC-407C (SI Units)
NOTES:
1. SST = Saturated Suction Temperature
2. kW
o
= Unit kW Cooling Capacity Output
3. kW
i =
Compressors kW Input
4. COP = Coefficient of Performance (based on compressor and fan input kW)
YCUL0060EB
AIR TEMPERATURE ON - CONDENSER (°C)
LCWT
(°C)
25°C
30°C
35°C
40°C
45°C
50°C
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
2.0
180.3
48.9
3.3
170.7
54.3
2.9
160.9
60.2
2.5
150.8
66.7
2.1
104.1
50.6
1.9
68.9
36.1
1.65*
3.0
186.8
49.2
3.4
176.9
54.7
2.9
166.7
60.7
2.5
156.4
67.2
2.2
108.2
50.9
1.9
71.6
36.2
1.7
4.0
193.5
49.6
3.5
183.3
55.1
3.0
172.8
61.1
2.6
162.2
67.7
2.2
112.1
51.3
2.0
74.2
36.5
1.8
5.0
200.3
50.1
3.6
189.8
55.5
3.1
178.9
61.6
2.7
168.0
68.2
2.3
116.5
51.5
2.0
77.1
36.6
1.8
6.0
207.2
50.5
3.7
196.4
56.0
3.2
185.3
62.0
2.7
173.9
68.7
2.3
120.8
51.8
2.1
80.0
36.8
1.9
7.0
214.3
51.0
3.8
203.2
56.4
3.3
191.7
62.6
2.8
180.0
69.3
2.4
125.3
52.2
2.2
83.1
36.9
2.0
8.0
221.6
51.5
3.9
210.1
56.9
3.4
198.3
63.1
2.9
186.3
69.9
2.5
129.8
52.5
2.2
86.2
37.1
2.0
9.0
229.0
52.0
4.0
217.2
57.5
3.4
205.0
63.6
3.0
192.7
70.5
2.5
134.5
52.9
2.3
89.4
37.3
2.1
10.0
236.6
52.5
4.1
224.4
58.0
3.5
211.9
64.2
3.0
199.2
71.1
2.6
139.3
53.2
2.4
92.7
37.5
2.2
11.0
244.4
53.0
4.2
231.8
58.6
3.6
219.0
64.8
3.1
153.7
48.5
2.8
144.3
53.6
2.4
96.0
37.7
2.2
12.0
252.2
53.6
4.3
239.4
59.2
3.7
226.2
65.4
3.2
159.0
48.8
2.9
106.4
34.1
2.7
99.5
37.9
2.3
YCUL0066EB
AIR TEMPERATURE ON - CONDENSER (°C)
LCWT
(°C)
25°C
30°C
35°C
40°C
45°C
50°C
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
2.0
199.9
51.0
3.5
189.7
56.7
3.1
179.3
63.0
2.6
168.7
69.9
2.2
158.7
76.8
1.9
76.8
38.2
1.8
3.0
207.3
51.3
3.7
196.8
57.0
3.1
185.9
63.3
2.7
175.0
70.2
2.3
163.7
77.9
2.0
79.8
38.3
1.8
4.0
214.8
51.6
3.8
203.9
57.3
3.2
192.8
63.7
2.8
181.4
70.7
2.4
169.8
78.3
2.0
82.9
38.4
1.9
5.0
222.4
51.9
3.9
211.2
57.7
3.3
199.7
64.1
2.9
188.0
71.1
2.5
176.1
78.8
2.1
86.0
38.6
2.0
6.0
230.2
52.3
4.0
218.6
58.1
3.4
206.8
64.5
3.0
194.7
71.6
2.5
182.3
79.3
2.2
89.3
38.7
2.0
7.0
238.1
52.7
4.1
226.2
58.5
3.5
214.1
65.0
3.0
201.6
72.1
2.6
188.8
79.9
2.2
92.7
38.8
2.1
8.0
246.2
53.1
4.2
233.9
59.0
3.6
221.4
65.5
3.1
208.6
72.6
2.7
102.8
35.1
2.5
96.1
39.0
2.2
9.0
254.4
53.6
4.3
241.8
59.5
3.7
228.9
66.0
3.2
215.7
73.1
2.7
106.5
35.2
2.6
99.6
39.1
2.2
10.0
262.8
54.0
4.4
249.9
59.9
3.8
236.6
66.5
3.3
223.0
73.7
2.8
110.3
35.3
2.7
103.3
39.3
2.3
11.0
271.3
54.5
4.5
258.0
60.5
3.9
244.4
67.0
3.4
230.4
74.3
2.9
114.3
35.5
2.8
107.0
39.4
2.4
12.0
280.0
55.0
4.6
266.4
61.0
4.0
252.4
67.6
3.5
238.0
74.9
3.0
118.3
35.6
2.9
110.8
39.6
2.5
YCUL0076EB
AIR TEMPERATURE ON - CONDENSER (°C)
LCWT
(°C)
25°C
30°C
35°C
40°C
45°C
50°C
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
2.0
219.4
59.7
3.3
207.1
66.4
2.8
194.7
73.8
2.4
182.3
81.8
2.1
170.1
90.4
1.8
109.5
61.3
1.6
3.0
227.4
60.2
3.4
214.7
66.9
2.9
201.8
74.3
2.5
189.1
82.4
2.1
176.6
91.0
1.8
113.8
61.6
1.7
4.0
235.4
60.7
3.5
222.4
67.4
3.0
209.2
74.9
2.6
196.1
83.0
2.2
152.9
71.8
2.0
117.9
62.3
1.7
5.0
243.6
61.2
3.6
230.3
67.9
3.1
216.7
75.4
2.6
203.2
83.6
2.3
158.7
72.2
2.0
122.5
62.6
1.8
6.0
252.1
61.7
3.7
238.4
68.4
3.2
224.3
76.1
2.7
210.5
84.3
2.3
164.6
72.7
2.1
127.2
62.9
1.8
7.0
260.8
62.2
3.8
246.6
69.0
3.3
232.3
76.6
2.8
218.0
85.0
2.4
170.7
73.1
2.1
132.1
63.2
1.9
8.0
269.7
62.8
3.9
255.0
69.7
3.3
240.3
77.3
2.9
225.7
85.6
2.4
176.9
73.6
2.2
137.1
63.6
2.0
9.0
278.7
63.4
4.0
263.7
70.3
3.4
248.6
77.9
2.9
233.5
86.4
2.5
183.3
74.0
2.3
142.2
63.9
2.0
10.0
288.1
64.0
4.1
272.6
70.9
3.5
257.0
78.6
3.0
241.6
87.1
2.6
189.9
74.5
2.3
147.5
64.3
2.1
11.0
297.6
64.6
4.2
281.6
71.6
3.6
265.6
79.4
3.1
249.9
87.9
2.6
196.6
75.0
2.4
152.8
64.7
2.1
12.0
307.3
65.2
4.3
290.9
72.3
3.7
274.5
80.1
3.2
258.3
88.7
2.7
203.5
75.6
2.5
158.5
65.0
2.2
YCUL0080EB
AIR TEMPERATURE ON - CONDENSER (°C)
LCWT
(°C)
25°C
30°C
35°C
40°C
45°C
50°C
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
KW
o
KW
i
COP
2.0
246.5
65.3
3.4
232.8
72.6
2.9
218.7
80.7
2.5
204.5
89.5
2.1
190.4
98.7
1.8
122.5
66.9
1.7
3.0
255.4
65.8
3.5
241.3
73.1
3.0
226.8
81.3
2.6
212.2
90.1
2.2
197.7
99.4
1.9
127.3
67.4
1.7
4.0
264.6
66.4
3.6
250.0
73.7
3.1
235.1
81.9
2.7
220.1
90.7
2.3
205.3 100.2
1.9
132.3
67.8
1.8
5.0
274.0
67.0
3.7
259.0
74.3
3.2
243.6
82.5
2.7
228.2
91.4
2.3
213.0 100.9
2.0
137.4
68.3
1.8
6.0
283.6
67.6
3.8
268.1
74.9
3.3
252.3
83.1
2.8
236.5
92.1
2.4
220.9 101.7
2.0
141.8
69.2
1.9
7.0
293.5
68.2
3.9
277.5
75.5
3.4
261.3
83.8
2.9
244.9
92.9
2.5
158.1
63.0
2.3
147.4
69.6
1.9
8.0
303.6
68.9
4.0
287.1
76.2
3.5
270.3
84.6
3.0
253.7
93.6
2.5
164.1
63.3
2.3
153.0
70.0
2.0
9.0
313.8
69.7
4.1
297.0
77.0
3.6
279.8
85.3
3.0
262.6
94.5
2.6
170.2
63.6
2.4
158.8
70.4
2.1
10.0
324.4
70.4
4.2
307.1
77.7
3.6
289.4
86.1
3.1
271.8
95.3
2.7
176.5
64.0
2.5
164.8
70.8
2.1
11.0
335.2
71.2
4.3
317.4
78.5
3.7
299.2
86.9
3.2
281.1
96.2
2.7
182.9
64.4
2.6
171.0
71.2
2.2
12.0
346.3
72.0
4.4
328.0
79.3
3.8
309.3
87.7
3.3
290.8
97.1
2.8
189.5
64.8
2.7
177.2
71.7
2.3