Indoor external static pressure (Hi)
Pa
40
40
Indoor noise level (Hi/Mid/Lo)
dB(A)
45/41/38
49/45/42
Dimension (W*H*D)
mm
1000×298×800
1000×298×800
Packing
(W*H*D)
mm
1205×370×940
1205×370×940
Indoor unit
Net/Gross weight
kg
36/43
38/45
Model
YSK55-4L
YSK55-4L
Input
W
110/104/98
110/104/98
Capacitor
uF
2.5uF/450V
2.5uF/450V
Outdoor
fan
motor
Speed
r/min
1280/1190/1000
1280/1190/1000
Number of rows
3
3
Tube pitch(a)x row pitch(b)
mm
25.4×22
25.4×22
Fin spacing
mm
1.7
1.7
Fin type
Hydrophilic aluminium
Hydrophilic aluminium
Tube outer dia.and type
mm
Ø
Ø
Ø
Ø
Ø
9.53,innergroove tube
Ø9.53,innergroove tube
Coil length x height x width
mm
775×660×44
770×810×44
Outdoor coil
Number of circuits
3
2
Outdoor air flow
m
3
/h
2400
3000
Outdoor noise level
dB(A)
48
52
Dimension (W*H*D)
mm
845×695×335
895×860×330
Packing (W*H*D)
mm
970X770X395
1043X915X395
Outdoor unit
Net/ Gross weight
kg
53/57
64/66
Refrigerant type/Quantity
g
R22/1850
R22/2600
Design pressure (high side/low side)
MPa
2.8/1.2
2.8/1.2
Liquid side
mm(inch)
6.35 (1/4)
9.53 (3/8)
Gas side
mm(inch)
12.7 (1/2)
16 (5/8)
Max. pipe length
m
20
20
Refrigerant
piping
Max. difference in level
m
10
10
Operation temp
ºC
17~30
17~30
Ambient temp
ºC
-7~45
-7~45
Application area
m
2
34~49
40~56
Qty’per 20’ /40’ /40'HQ
set
38/78/90
34/68/80
Notes:
1. Nominal cooling capacities are based on the following conditions:
Indoor temp: 27°CDB, 19°CWB; Outdoor temp: 35°CDB; Equivalent ref. piping: 7.5m (horizontal)
2. Nominal heating capacities are based on the following conditions:
Indoor temp: 20°CDB; Outdoor temp: 7°CDB, 6°CWB; Equivalent ref. Piping: 7.5m(horizontal)
3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from
an anechoic room.