1034868-UIM-A-0513
Johnson Controls Unitary Products
43
SECTION XII: WIRING DIAGRAM
FIGURE 46:
Wiring Diagram
Wiring Diagram 96% Two-Stage COMM Furnace
SERVICING THIS UNIT
OPEN ALL DISCONNECTS BEFORE
CAUTION
PRECAUTION
OUVREZ LES DISJONCTEURS AVANT
DE PROCEDER AVEC LE SERVICE
1034866-UWD-A-0413
Fault Code Retrieval
To retrieve fault codes, push and release ERROR button on control board. The LED will flash the
last five error codes, beginning with the most recent. If there are no fault codes in memory, the LED
will give two green flashes. To clear the fault code memory, push and hold the ERROR button for
at least five seconds. The LED will give three green flashes when the memory has been cleared.
Notice - Only a qualified service technician should use this feature.
Fault code retrieval functions will work only if there are no active thermostat signals.
NOTES:
1. Si l'un des fils d'origine fourni avec ce four doit filage doit être remplacé,
il doit être remplacé avec le fil ayant un degré de température d'au
moins 221 degrés F (105 degrés C ).
2. Seulement des marettes pour fil de cuivre.
NOTES:
1. If any of the original wire as supplied with the furnace must be replaced,
it must be replaced with wiring material having a temperature rating of at
least 221 degrees F (105 degrees C).
2. Connectors suitable for copper conductors only.
Flashes
Diagnostic Fault Codes
Fault Condition
Power Off
Normal Operation
Normal Operation with call for heat
Low flame sense current
No G from thermostat
Control Failure
Flame present with gas off
Check pressure switch wiring
Vent OR termination problem
Airflow problem OR open fuse
Flame Rollout OR open fuse
Repeated 3 Red
Failed to light burners
Loss of flame during call for heat
Hot/Neutral reversed OR poor
ground/neutral
Gas valve shorted "ON"
Check blower motor/wiring
Vent OR termination problem
None
Slow Green
Slow Amber
Rapid Amber
4 Amber
Steady on Red
1 Red
2 Red
3 Red
4 Red
5 Red
6 Red
7 Red
8 Red
9 Red
10 Red
11 Red
13 Red
DS -
ROS -
XFMR -
HSI -
PF-
PS1 -
PS2 -
PS3 -
IDM -
EAC -
LS -
HUM -
Legend
Door switch
Rollout switch
Transformer
Hot surface igniter
Power factor choke
Pressure switch, 1 stage
Pressure switch, 2 stage
Pressure switch, condensate
Inducer motor
Electronic air cleaner
Limit switch
Humidifier
DS -
ROS -
XFMR -
HSI -
PF -
PS1 -
PS2-
PS3-
IDM-
EAC-
LS -
HUM -
Legende
Commutateur de porte
Commutateur de roulement
Transformeur
Ignition de surface chaud
Transformeur de facteur
de puissance
Commutateur de pression,
premier stage
Commutateur de pression,
deuxieme stage
Commutateur de pression,
condensation
D'induct moteur
Filtre électrique
Commutateur de limite
Humidificateur
1600/2000 CFM
MODELS ONLY
ORG/BLK
NO
C
DOOR N.O.SW
115VAC LINE
115VAC NEUT.
BLK
BLK
PF
HUM
EAC
4
1
2
3
6
5
9
8
11
10
7
12
1600/2000 CFM
MODELS ONLY
ROS1
HI
C
M
GAS VALVE
CONTROLS
TO AIR CONDITIONER
ROOM THERMOSTAT
2-STAGE COOLING
2-STAGE HEATING
COMMON T'STAT CONNECTION
Y2
Y
W1
W
R
C
G
Y1
W2
W2
Y1
G
C
R
W
W1
Y
Y2
HIGH
LOW
IDM
EAC
HUMIDIFIER
BLOWER
MOTOR
POWER SUPPLY 115-1-60
GND
DS
C
NO
HSI
N.O.SW DOOR SWITCH
C
PS2
NO
GND
COM
115V
24V SEC
PRI
1T (40VA)
2ND STAGE
LS
ROS2
PF
NO
PS1
C
1ST STAGE
RED/GRN
FLAME SENSOR
PUR
24V SEC
LOAD
115V PRI
LINE
P3/S3
2
1
WHT
WHT
HSI
BRN
BLK
WHT
BLOWER
MOTOR
GND
GRN
(16) ORG
(15) GRN
(9) EMPTY
(10) RED
(11) EMPTY
(12) EMPTY
(13) EMPTY
(14) EMPTY
(1) EMPTY
(2) EMPTY
(3) BLK/WHT
(4) EMPTY
(5) EMPTY
(6) EMPTY
(7) EMPTY
(8) PUR
GND
EAC
HUM
FURNACE CONTROL
NEUTRALS
C G R
W/W1
Y/Y2
Y1
W2
DE-
HUM
O
PS3
NO
RED/BLK
ROS1
RED/WHT
RED
LS
ROS2
RED
C
NO
GAS VALVE
BLK
WHT
ORG
PS2
M
C
HI
YEL
WHT
YEL
BLK
WHT
RED
BLK
GRN
M
DI
D
N
G
3
2
1
WHT
ORG
PUR
RED
GRN
BLK/WHT
BRN
BLU
WHT
BLK
GRY
GRY
BRN
4
1
2
3
6 5
4 1
2
3
6
5
4
1
2
3
5
C
GRN
GRN
NO
PS3
C
PS1
NO
C
WHT