1034868-UIM-A-0513
Johnson Controls Unitary Products
23
FIGURE 29:
Horizontal Left Configuration
HORIZONT
AL
-
LEFT
INDUCER
ROT
A
TED
HORIZONT
AL
-
LEFT
INDUCER
AS
RECEIVED
AIRFLOW
AIRFLOW
Move
pressure
switch
hose
to
this
position.
NOTE:
May
require
the
longer
hose
that
is
provided
with
wider
cabinet
s.
Move
rain
gutter
hose
to
this
position
NOTE:
May
require
hose
extension
that
is
provided
with
wider
cabinet
s.
Move
rain
gutter
hose
to
this
position.
Move
pressure
switch
hose
to
this
position.
NOTE:
May
require
the
longer
hose
that
is
provided
with
wider
cabinet
s.
Change
condensate
drain
connection
to
the
90°
fitting
provided.
Move
condensate
drain
hose
to
this
position.
Move
rain
gutter
hose
to
this
position
NOTE:
May
require
hose
extension
that
is
provided
with
wider
cabinet
s.
Move
condensate
drain
hose
to
this
position.
Change
condensate
drain
connection
to
the
90°
fitting
provided.
When
drain
hose
routing
changes
are
required,
be
sure
to
cap
all
unused
openings.
If
rerouting
hoses
-
excess
length
should
be
cut
of
f
s
o
that
no
sagging
loop
s
will
collect
and
hold
condensate,
which
will
cause
the
furnace
to
not
operate.
1
2
3
4
5
3
4
2
1